Blizzard Lighting Super-G 150 User Manual Download Page 9

Page 9

Super-G™ 150 User Manual - Rev. A  

 

 

(c) 2018 Blizzard Lighting, LLC

Fixture Linking (Master/Slave Mode)

1.  Connect the (male) 3-pin connector side of the DMX cable to the output (female) 

3-pin connector of the first fixture.

 

2. 

Connect the end of the cable coming from the first fixture which will have a (female) 

3-pin connector to the input connector of the next fixture consisting of a (male) 3-pin 

connector. Then, proceed to connect from the output as stated above to the input of 

the following fixture and so on.

Clamp Mounting

This fixture provides a mounting bracket assembly that secures the bottom of the base, the 

“Omega Brackets,” and the safety cable rigging point together. When mounting this fixture 

to truss, be sure to secure an appropriately rated clamp to the omega bracket using an 

M10 screw fitted through the center hole of the “omega bracket”.

1/4 Turn 

1/4 Turn 

2

3

1

1.) Clamp

2.) Omega Bracket

3.) ¼ Turn Quick Locks

Securing the Fixture

Regardless of the rigging option you choose for your fixtures always be sure to secure 

your fixture with a safety cable. Be sure to only use the designated rigging point found on 

the underside of the base assembly for the safety cable. Never secure a safety cable to a 

carrying handle.

Summary of Contents for Super-G 150

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2018...

Page 2: ...DMX Control 8 Fixture Linking Master Slave Mode 9 Clamp Mounting 9 Securing the Fixture 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 DMX Mode 12 Set the Starting D...

Page 3: ...ase verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed curr...

Page 4: ...lation slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER...

Page 5: ...9 x 14 3 inches 170 x 226 x 362 mm Weight 16 2 lbs 7 34 kg CONTROL Protocol USITT DMX 512 DMX Channels 12 13 15 2 inch TFT LCD display menu with 4 button control panel Operating Modes Standalone Maste...

Page 6: ...ure 1 Super G 150 Pin Up Picture Figure 2 The Rear Connections 3 Pin DMX Out Power Output Power Input 3 Pin DMX In Fuse Holder Figure 1 Super G 150 Pin Up Picture 150W LED Light Source Carry Handle 4...

Page 7: ...ted splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is...

Page 8: ...chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data 1 Primary Data Link Pin 2 Pin 2 Data 1 Primary Data Link Pin 3 Pin 3 Data 2...

Page 9: ...p Mounting This fixture provides a mounting bracket assembly that secures the bottom of the base the Omega Brackets and the safety cable rigging point together When mounting this fixture to truss be s...

Page 10: ...and confirm store the current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel display shows th...

Page 11: ...NTER Motor reset Yes No Option Pan Tilt Swap Swap pan tilt channels On Off Pan Reverse Pan reverse On Off Tilt Reverse Tilt reverse On Off Shortcut ON OFF Wheels use shortest distance between effects...

Page 12: ...Device Options The options menu contains various configurable settings for the fixture Pan Tilt Swap Pan Tilt Reverse 1 Navigate the menu until you reach Option and press ENTER 2 Then navigate to Inve...

Page 13: ...nfirm your selection Setup Options The setup menu contains password protected calibration and mic settings Password password 008 1 Navigate the menu until you reach Setup and press ENTER 2 Then naviga...

Page 14: ...010 011 023 024 036 037 049 050 062 063 075 076 088 089 101 102 114 115 127 128 140 141 153 154 166 167 179 180 217 218 255 Color Wheel Open Color 1 Color 1 Color 2 Color 2 Color 2 Color 3 Color 3 Co...

Page 15: ...on 0 540 Angle Index Forward Rotation fast slow Stop Reverse Rotation slow fast 9 10 12 000 127 128 255 Prism Open 3 Facet Prism 10 11 13 000 127 128 190 191 192 193 255 Prism Rotation 0 540 Angle Ind...

Page 16: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the...

Page 17: ...wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for se...

Page 18: ...ons 14mm inner dimensions Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 12 13 15 channel DMX modes Input 3 pin XLR Male Output 3 pin XLR Fem...

Page 19: ...power connectors fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG Neutrik USA and their related entities however they are not manufactured...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: