Motif™ Metro User Manual Rev. A 

© 2020 Blizzard Lighting, LLC

Take It To The Next Level: Setting Up DMX Control

Step 1: 

Connect the male connector of the DMX cable to the female connector 

(output) on the controller.

Step 2:

 Connect the female connector of the 

DMX cable to the first fixture’s male connector 

(input).  

Note:

 It doesn’t matter which fixture address is the first one 

connected.  We recommend connecting the fixtures in terms 

of their proximity to the controller, rather than connecting the 

lowest fixture number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture to 

ensure best communication.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 3-pin DMX output connector, you will need to use a 3-pin to 5-pin adapter. If 

you’d like to build your own, the chart below details a proper cable conversion:

Conductor

5-Pin Female (Output)

3-Pin Male (Input)

Ground/Shield

Pin 1

Pin 1

Data 1- (Primary Data Link)

Pin 2

Pin 2

Data 1+ (Primary Data Link)

Pin 3

Pin 3

Data 2- (Optional Secondary Data Link)

Pin 4

Pin 4

Data 2+ (Optional Secondary Data Link)

Pin 5

Pin 5

DMX OUT

DMX IN

First 

Fixture 

in Chain

Next 

Fixture 

in Chain

DMX OUT

DMX IN

3

1

2

5

4

3

1

2

5

4

INPUT

OUTPUT

Common

DMX +

DMX -

4/5 = NC

Cable Connectors

Cables must have a male XLR connector on one end and a female XLR connec-

tor on the other end. (Duh!)

A Word on Termination:

DMX is a resilient communication protocol, however 

errors still occasionally occur. Termination reduces signal 

errors, and therefore best practices include use of a 

terminator in all circumstances. If you are experiencing 

problems with erratic fixture behavior, especially over 

long signal cable runs, a terminator may help improve 

performance.

To build your own DMX Terminator:

Obtain a 120-ohm, 1/4-watt resistor, and wire it between pins 2 & 3 of the last fixture. They are also 

readily available from specialty retailers.

CAUTION:

 Do not allow contact between the common and the fixture’s chassis 

ground. Grounding the common can cause a ground loop, and your fixture may 

perform erratically. Test cables with an ohm meter to verify correct polarity and 

to make sure the pins are not grounded or shorted to the shield or each other.

Summary of Contents for Motif Metro

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2020 SUITABLE FOR OUTDOOR USE...

Page 2: ...nt 7 Connecting A Bunch of Motif Metro Fixtures 7 Data DMX Cabling 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting Up DMX Control 8 Fixture Linking M S Mode 9 Mounting Rigging...

Page 3: ...packing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used so...

Page 4: ...S disconnect from the power source before servicing ALWAYS secure mounted fixtures with a safety cable NEVER carry the fixture by its head Use its carrying handles DO NOT operate at ambient temperatur...

Page 5: ...lt head Tough as nails aluminum ABS enclosure IP rated locking power and 3 pin DMX connections Dual omega brackets with 1 4 turn fasteners Control Protocol USITT DMX 512 DMX channels 4 6 9 channel mod...

Page 6: ...r Manual Rev A 2020 Blizzard Lighting LLC The Rear Connections Motif Metro Pin Up Picture 60 10W 4 in 1 RGBW LEDs 180 Tilt Head Cast Aluminum ABS Enclosure Power In Power Out DMX In DMX Out 4 button L...

Page 7: ...connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run d...

Page 8: ...rimary Data Link Pin 3 Pin 3 Data 2 Optional Secondary Data Link Pin 4 Pin 4 Data 2 Optional Secondary Data Link Pin 5 Pin 5 DMX OUT DMX IN First Fixture in Chain Next Fixture in Chain DMX OUT DMX IN...

Page 9: ...fixture may be mounted in any SAFE position provided there is enough room for ventilation The fan or vents pathway must never obstructed A mounting bracket assembly is provided that secures the botto...

Page 10: ...ut changing the value press the MENU button 4 OPERATING ADJUSTMENTS The Control Panel All of the features and different modes possible with this fixture are accessed by using the control panel on the...

Page 11: ...Blue Intensity 0 255 6 White White Intensity 0 255 3 Auto 1 Run Mode Stop Flash Fade Pulse 2 Speed Auto Speed 0 255 4 System 1 Host Mode ON master OFF 2 Language English Chinese 3 Backlight Off Black...

Page 12: ...ost Mode and then press ENTER Then highlight ON and press ENTER 4 On following fixtures verify that this setting is set to OFF 5 If the DMX signal is lost while operating it will default to the set Au...

Page 13: ...nction Red Green Blue White Yellow Magenta Cyan 8 000 100 101 150 151 200 201 255 Auto Mode No Function Flash Fade Pulse 9 000 255 Auto Speed Speed slow fast Dimming Modes Allows users to set the fixt...

Page 14: ...That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But l...

Page 15: ...4 in 1 RGBW LEDs Optical Beam Angle 40 beam angle Luminous Intensity 13 220 lux 2 5 meters 3 414 lux 5 meters 1 610 lux 7 5 meters 887 lux 10 meters Movement Range Tilt 180 manual tilt Thermal Max Ope...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: