Blizzard Lighting mikrokassette Manual Download Page 7

Page 7

Mikrokassette™ Manual - Rev. A    

 

© 2020 Blizzard Lighting, LLC

Fuse Replacement

With a flat head screwdriver, wedge the fuse 

holder out of its housing. Remove the damaged 

fuse from its holder and replace with exact same 

type fuse.

Connecting A Bunch of Mikrokassette's

You will need a serial data link to run light shows 

using a DMX-512 controller or to run shows on 

two or more fixtures set to sync in master/slave operating mode. The combined 

number of channels required by all the fixtures on a serial data link determines 

the number of fixtures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line. Also, 

connecting more than 32 fixtures on one serial data link without the use of a 

DMX optically-isolated splitter may result in deterioration of the digital DMX 

signal. The maximum recommended cable-run distance is 500 meters (1640 

ft).  The maximum recommended number of fixtures on a serial data link is 32 

fixtures.

Data/DMX Cabling

To link fixtures together you’ll need data cables.  You should use data-grade 

cables that can carry a high quality signal and are less prone to electromagnetic 

interference.

For instance, Belden© 9841 meets the specifications for EIA RS-485 

applications. Standard microphone cables will “probably” be OK, but note that 

they cannot transmit DMX data as reliably over long distances.  In any event, 

the cable should have the following characteristics:

 

2-conductor twisted pair plus a shield

 

Maximum capacitance between conductors – 30 pF/ft.

 

Maximum capacitance between conductor & shield – 55 pF/ft.

 

Maximum resistance of 20 ohms / 1000 ft.

 

Nominal impedance 100 – 140 ohms

Before replacing a fuse, disconnect the power cord. 

ALWAYS replace with the same type and rating of fuse.

3. SETUP

Summary of Contents for mikrokassette

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2020...

Page 2: ...kassette s 7 Data DMX Cabling 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting Up DMX Control 8 Fixture Linking M S Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Con...

Page 3: ...Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 1...

Page 4: ...ion slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER ca...

Page 5: ...hite LED dimming 4 button control panel with LED display Easy to use IR remote control 3 pin DMX input output IEC power in out Compact black metal housing with mounting brackets Control Protocol USITT...

Page 6: ...e Manual Rev A 2020 Blizzard Lighting LLC The Rear Connections Mikrokassette Pin Up Picture 5 10W 4 in 1 RGBW LEDs Locking Knob Remote Sensor Mounting Brackets Microphone DMX In Power In DMX Out Power...

Page 7: ...t in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX C...

Page 8: ...between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and...

Page 9: ...for this type of setup and configuration DMX OUT DMX IN First Fixture in Chain Next Fixture in Chain DMX OUT DMX IN Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Page 10: ...n To return to the previous option or menu without changing the value press the MENU button 4 OPERATING ADJUSTMENTS The Control Panel All of the features and different modes possible with the mikrokas...

Page 11: ...meters 0 Function switch dimming or static mode The remote control has 2 modes dimming mode static mode To switch between these modes press the 0 button Depending on the mode you are in the functional...

Page 12: ...un factory installed programs Auto Mode 1 Navigate the menu until you reach AUTO and press ENTER Color Jump Color Fade 1 Navigate the menu until you reach JUNP color jump or FAdE color fade and press...

Page 13: ...el Value What It Does 1 000 255 Dimmer 0 100 2 000 255 Red Intensity 0 100 3 000 255 Green Intensity 0 100 4 000 255 Blue Intensity 0 100 5 000 255 White Intensity 0 100 6 000 255 Strobe slow fast Fun...

Page 14: ...That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But li...

Page 15: ...Fuse 3A 250V Light Source LED 5 10W 4 in 1 RGBW LEDs Beam Angle 25 Luminance 1 085 lux 2 5M 248 lux 5M Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: