Keeping Your Mikrokassette™ As Good As New

The fixture you’ve received is a rugged, tough piece of pro lighting equipment, 

and as long as you take care of it, it will take care of you. That said, you’ll need 

to take care of it if you want it to operate as designed. You should keep the 

fixture clean, especially if you are using it in an environment with a lot of dust, 

fog, haze, wild animals, wild teenagers or spilled drinks.  

Cleaning the optics routinely with a suitable glass cleaner will greatly improve 

the quality of light output.  Keeping the fans free of dust and debris will keep 

the fixture running cool and prevent damage from overheating.  

In transit, keep the fixtures in cases.  You wouldn’t throw a prized guitar, 

drumset, or other piece of expensive gear into a gear trailer without a case, 

and similarly, you shouldn’t even think about doing it with your shiny new light 

fixtures.  

Common sense and taking care of your fixtures will be the single biggest thing 

you can do to keep them running at peak performance and let you worry about 

designing a great light show, putting on a great concert, or maximizing your 

client’s satisfaction and “wow factor.”  That’s what it’s all about, after all!

Returns (Gasp!)

We’ve taken a lot of precautions to make sure you never even have to worry 

about sending a defective unit back, or sending a unit in for service.  But, 

like any complex piece of equipment designed and built by humans, once in a 

while, something doesn’t go as planned.  If you find yourself with a fixture that 

isn’t behaving like a good little fixture should, you’ll need to obtain a Return 

Authorization (RA).  

Don’t worry, this is easy.  Just  visit www.blizzardpro.com/support and open a 

support ticket, and we’ll issue you an RA. Then, you’ll need to send the unit to 

us using a trackable, pre-paid freight method. We suggest using USPS Priority 

or UPS.  Make sure you carefully pack the fixture for transit, and whenever 

possible, use the original box & packing for shipping.

When returning your fixture for service, be sure to include the following:

 

1.) Your contact information (Name, Address, Phone Number, Email address).

 

2.) The RA# issued to you

 

3.) A brief description of the problem/symptoms.

We will, at our discretion, repair or replace the fixture.  Please remember 

that any shipping damage which occurs in transit to us is the customer’s 

responsibility, so pack it well!

Shipping Issues

Damage incurred in shipping is the responsibility of the shipper, and 

must be reported to the carrier immediately upon receipt of the items.  

Claims must be made within seven (7) days of receipt.

5. APPENDIX

Summary of Contents for mikrokassette

Page 1: ...Blizzard Lighting LLC http www blizzardpro com Waukesha WI USA Copyright c 2020...

Page 2: ...kassette s 7 Data DMX Cabling 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting Up DMX Control 8 Fixture Linking M S Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Con...

Page 3: ...Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 1...

Page 4: ...ion slots are blocked ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER ca...

Page 5: ...hite LED dimming 4 button control panel with LED display Easy to use IR remote control 3 pin DMX input output IEC power in out Compact black metal housing with mounting brackets Control Protocol USITT...

Page 6: ...e Manual Rev A 2020 Blizzard Lighting LLC The Rear Connections Mikrokassette Pin Up Picture 5 10W 4 in 1 RGBW LEDs Locking Knob Remote Sensor Mounting Brackets Microphone DMX In Power In DMX Out Power...

Page 7: ...t in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX C...

Page 8: ...between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and...

Page 9: ...for this type of setup and configuration DMX OUT DMX IN First Fixture in Chain Next Fixture in Chain DMX OUT DMX IN Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Page 10: ...n To return to the previous option or menu without changing the value press the MENU button 4 OPERATING ADJUSTMENTS The Control Panel All of the features and different modes possible with the mikrokas...

Page 11: ...meters 0 Function switch dimming or static mode The remote control has 2 modes dimming mode static mode To switch between these modes press the 0 button Depending on the mode you are in the functional...

Page 12: ...un factory installed programs Auto Mode 1 Navigate the menu until you reach AUTO and press ENTER Color Jump Color Fade 1 Navigate the menu until you reach JUNP color jump or FAdE color fade and press...

Page 13: ...el Value What It Does 1 000 255 Dimmer 0 100 2 000 255 Red Intensity 0 100 3 000 255 Green Intensity 0 100 4 000 255 Blue Intensity 0 100 5 000 255 White Intensity 0 100 6 000 255 Strobe slow fast Fun...

Page 14: ...That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But li...

Page 15: ...Fuse 3A 250V Light Source LED 5 10W 4 in 1 RGBW LEDs Beam Angle 25 Luminance 1 085 lux 2 5M 248 lux 5M Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX...

Page 16: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: