Blizzard Lighting LB HEX User Manual Download Page 8

Page 8

LB-Hex User Manual Rev. B  

 

 

© 2017 Blizzard Lighting, LLC

Cable Connectors

Cables must have a male XLR connector on one end and a female XLR 

connector on the other end.  (Duh!)

CAUTION:

 Do not allow contact between the common and the fix

-

ture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.  

They are widely available over the internet and from specialty retailers  If you’d like to build your own, the 

chart below details a proper cable conversion:

Conductor

3-Pin Female 

(Output)

5-Pin Male 

(Input)

Ground/Shield

Pin 1

Pin 1

DMX Data (-)

Pin 2

Pin 2

DMX Data (+)

Pin 3

Pin 3

Not Used.

No Connection.

No Connection.

Not Used.

No Connection.

No Connection.

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the 

DMX cable to the female connector (output) 

on the controller.

Step 2:

 Connect the female connector of the 

DMX cable to the first fixture’s male connec

-

tor (input).  

Note:

  It doesn’t matter which 

fixture address is the first one connected.  

We recommend connecting the fixtures in 

terms of their proximity to the controller, 

rather than connecting the lowest fixture 

number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture 

to ensure best communication.

Summary of Contents for LB HEX

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2017...

Page 2: ...uh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 Using this fixture with the wiCICLE Wireless DMX System 10 4 Operating Adjustments 12 Nav...

Page 3: ...er supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check t...

Page 4: ...g or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambien...

Page 5: ...Dual bracket for flexibility in mounting Flicker free constant current LED driver 3 pin male input and 3 pin female output PowerCon compatible AC power In Out connectors Can directly power the wiCICLE...

Page 6: ...LC Figure 1 The LB Hex Pin Up Picture 12 6 in 1 RGBAW UV LEDs Heavy Duty Composite Housing Secure Grip Locking Knobs Figure 2 The Rear Connections Power Out DMX In DMX Out Microphone Power In Mic Sens...

Page 7: ...erial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration...

Page 8: ...e to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Con...

Page 9: ...Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is eno...

Page 10: ...to a DMX chain Some of these programs will automatically run unless the fixture is set to slave mode These fixtures typically sense DMX automatically and switch to DMX mode upon receiving DMX signal o...

Page 11: ...current selection UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel LED display shows the menu items you s...

Page 12: ...rolled by any universal DMX controller Set the Starting DMX Address The default mode for the fixture is DMX so the first menu item that you can edit is the starting DMX address 1 Navigate the main men...

Page 13: ...000 255 0 100 3 Press the ENTER button to confirm Blue 1 Navigate the main menu until you reach bL and press ENTER 2 Use the UP DOWN buttons to adjust blue 000 255 0 100 3 Press the ENTER button to c...

Page 14: ...29 030 039 040 049 050 059 060 069 070 079 080 089 090 099 100 109 110 119 120 129 130 139 140 255 Programs Auto and Sound Active Dimmer Speed Program 1 R G B jump Program 2 R G B fade in out Program...

Page 15: ...in mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the fir...

Page 16: ...tor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service Bu...

Page 17: ...ntless words Warranty 2 year limited warranty does not cover malfunction caused by damage to LEDs Troubleshooting Symptom Solution Fixture Auto Shut Off Check the fan in the fixture If it is stopped o...

Page 18: ...m DISCLAIMER The power connector fitted to the fixture and fixture cord are designed for compatibility with products manufactured by Neutrik AG Neutrik USA and their related entities however they are...

Page 19: ...compatible input 2 Upper lamp pressing plate 12 Red PVC 3 Under lamp pressing plate 13 PCB DMX canon socket 4 Lamps 14 Power supply 5 Copper pillar 15 Master PCB 6 PCB lamp board 16 Outer bracket 7 Ra...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: