background image

Page 3

HushPar Infiniwhite Manual Rev. A   

 

© 2014 Blizzard Lighting, LLC

1. GETTING STARTED

What’s In The Box?

 

 

• 1 x HushPar™ Infiniwhite 500 Professional LED PAR Fixture

              • This Lovely User Manual

Getting It Out Of The Box

 

Congratulations on purchasing one of the most rocking box-shaped PAR fixtures any-

where!  Now that you’ve got your HushPar™ Infiniwhite 500 (or hopefully, 

HushPares!

), 

you should carefully unpack the box and check the contents to ensure that all parts are 

present and in good condition. If anything looks as if it has been damaged in transit, 

notify the shipper immediately and keep the packing material for inspection.  Again, 

please save the carton and all packing materials. If a fixture must be returned to the 

factory, it is important that the fixture be returned in the original factory box and pack-

ing.

Powering Up!

 

All fixtures must be powered directly off a switched circuit and 

cannot be run off a 

rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch

.  

AC Voltage Switch -

 Not all fixtures have a voltage select switch, so please verify that 

the fixture you receive is suitable for your local power supply.  See the label on the 

fixture or refer to the fixture’s specifications chart for more information.  A fixture’s 

listed current rating is its average current draw under normal conditions. Check the 

fixture or device carefully to make sure that if a voltage selection switch exists that it is 

set to the correct line voltage you will use.

 

Warning! 

Verify that the voltage select switch on your unit matches the line 

voltage applied. Damage to your fixture may result if the line voltage applied 

does not match the voltage indicated on the voltage selector switch. All 

fixtures must be connected to circuits with a suitable Ground (Earthing).

Getting A Hold Of Us

If something is wrong, just give us a call or send an email.  We’ll be happy to 

help, honest. 

 

Blizzard Lighting

N16 W23390 Stoneridge Dr. Suite E

Waukesha, WI 53188 USA

www.blizzardlighting.com

414-395-8365

Email: [email protected]

Disclaimer:

 The information and specifications contained in this document are subject 

to change without notice. Blizzard Lighting™ assumes no responsibility or liability 

for any errors or omissions that may appear in this user manual. Blizzard Lighting™ 

reserves the right to update the existing document or to create a new document to 

correct any errors or omissions at any time. You can download the latest version of this 

document from www.blizzardlighting.com.

Author:

Date:

Last Edited:

Date:

J. Thomas

01/14/2014

J. Thomas

01/14/2014

Summary of Contents for HUSH PAR Infiniwhite 500

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2014 HUSHPAR Infiniwhite TM 500...

Page 2: ...Replacement 7 Connecting A Bunch Of HushPar Infiniwhite 500 PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master...

Page 3: ...e fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefull...

Page 4: ...servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate...

Page 5: ...nstalled optics 25 degree Constant current driver 500MA PWM Dimmer 400HZ 16666 steps Amber 590 595nm WW 3000 3300K CW 8000 9000K DMX Quick Reference 7 8 Channel Mode Channel 7 Channel 8 Channel 1 Dimm...

Page 6: ...Blizzard Lighting LLC Figure 1 The HushPar Infiniwhite 500 Pin Up Picture Figure 2 The Rear Connections LED Display DMX In DMX Out Menu Buttons High Power 5w 3 in 1 LEDs Heavy duty Die Cast Aluminum E...

Page 7: ...nk can support Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitte...

Page 8: ...like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No...

Page 9: ...the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Page 10: ...r DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the...

Page 11: ...nnel DMX mode 3CH 3 channel DMX mode SP SP00 SP15 Speed adjustments 0 15 Pr Pr00 Pr15 Built in programs 0 15 ASC AC00 AC15 Auto mode 0 15 FAdE FA00 FA15 Fade settings 0 15 FLAS FL00 FL15 Flash strobe...

Page 12: ...the ENTER button to confirm 3 To use the fixture in automatic mode select ASC and press the ENTER button Then use the UP DOWN to choose from AS00 AS15 then press the ENTER button to confirm 4 Adjust...

Page 13: ...9 030 039 040 049 050 069 070 079 080 089 090 109 110 119 120 129 130 149 150 159 160 169 170 189 190 199 200 219 220 229 230 249 250 255 Color Saturation Invalid A 100 A85 A C 15 A60 A C 40 A C 100 A...

Page 14: ...199 200 219 220 229 230 249 250 255 Color Saturation Invalid A 100 A85 A C 15 A60 A C 40 A C 100 A C 85 C15 A C 60 C40 C 100 C85 W15 C60 W40 W 100 W85 C W 15 W60 C W 40 C W 100 C W 50 A W 50 A W 100 A...

Page 15: ...r cor rect mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of speed adjust ment No Power Check fuse AC cord and circuit for malfunction Blown Fus...

Page 16: ...3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the...

Page 17: ...nt s satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sen...

Page 18: ...Consumption 90W Light Source LED 18x 5W 3 in 1 LEDs 100 000 hours Optical Beam Angle 25 degree optics Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX C...

Page 19: ...Page 19 HushPar Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC This page left intentionally blank...

Page 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: