Blizzard Lighting Flurry Wash User Manual Download Page 5

Page 9

Flurry Wash Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

Fixture Linking (Master/Slave Mode)

1.  Connect the (male) 3 pin connector side of the 

DMX cable to the output (female) 3 pin connector of 

the fi rst fi xture.

2.  Connect the end of the cable coming from the 

fi rst fi xture which will have a (female) 3 pin connec-

tor to the input connector of the next fi xture con-

sisting of a (male) 3 pin connector. Then, proceed 

to connect from the output as stated above to the 

input of the following fi xture and so on.

A quick note:  Often, 

the setup for Master-

Slave and Standalone 

operation requires that 

the fi rst fi xture in the 

chain be initialized for 

this purpose via either 

settings in the control 

panel or DIP-switches. 

Secondarily, the fi xtures 

that follow may also re-

quire a slave setting. 

Check the “Operating Adjustments” section in this manual for com-

plete instructions for this type of setup and confi guration.

Mounting & Rigging
This fi xture may be mounted in any SAFE position provided there is 

enough room for ventilation.

It is important never to obstruct the fan or vents pathway. Mount the 

fi xture using a suitable “C” or “O” type clamp.  The clamp should be 

rated to hold at least 10x the fi xture’s weight to ensure structural sta-

bility.  Do not mount to surfaces with unknown strength, and ensure 

properly “rated” rigging is used when mounting fi xutres overhead.

Adjust the angle of the fi xture by loosening both knobs and tilting the 

fi xture. After fi nding the desired position, retighten both knobs.

•  When selecting installation location, take into consideration lamp 

replacement access (if applicable) and routine maintenance.
•  Safety cables MUST ALWAYS be used.
•  Never mount in places where the fi xture will be exposed to rain, 

high humidity, extreme temperature changes or restricted ventilation.

Page 10

Flurry Wash Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

4. OPERATING ADJUSTMENTS

The Control Panel

All the goodies and different modes possible with the Flurry™ Wash are 

accessed by using the control panel on the front of the fi xture.  There 

are 4 control buttons below the LED display which allow you to navi-

gate through the various control panel menus.

<MODE/ESC> 
Is used to initially access the control panel system, and also navigate 

to the previous higher-level menu item.

<UP>
Scrolls through menu items and numbers in ascending order.

<DOWN> 
Scrolls through menu items and numbers in descending order.

<ENTER>  
Is used to select and confi rm/store the current selection.

The Control Panel LED Display shows the menu items you select from 

the menu map on page #11. When a menu function is selected, the 

display will show immediately the fi rst available option for the selected 

menu function. To select a menu item, press <ENTER>.

Press the <MODE/ESC> button repeatedly until you reach the desired 

menu function. Use the <UP> and <DOWN> buttons to navigate the 

menu options. Press the <ENTER> button to select the menu function 

currently displayed, or to enable a menu option. To return to the previ-

ous option or menu without changing the value, press the 

<MODE/ESC> button.

Summary of Contents for Flurry Wash

Page 1: ...5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 Ad...

Page 2: ...thing Getting A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting 2705 Brookview Ct Brookfield WI 53005 USA support blizzardlighting...

Page 3: ...LED display menu with invert Reset to factory settings option Display auto on off Pan tilt invert option Fan cooled OPTIONAL CONTROLLERS Easy Controller CA 9 DMX Quick Reference 13 Channel Mode Channe...

Page 4: ...apacitance between conductors 30 pF ft Maximum capacitance between conductor shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 8 Flurry Wash Manual Rev A Copyri...

Page 5: ...ting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance Safe...

Page 6: ...the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE DMX CHANNEL CONFIGURATION 1 Press the MODE ESC button until it shows or 2 Use the UP DOWN buttons to set to the de...

Page 7: ...act as follows Button What it Does Standby Blackout Function 1st click Strobe On 2nd click Strobe Off Mode 1st click Sound Active Mode Remote LED will be on 2nd click Auto Mode LED will be off DMX Mod...

Page 8: ...ble No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Too Fast Slow Check to ensure pr...

Page 9: ...to be output per packet and in fact it is very uncommon to find all 512 used The fewer channels are used the higher the refresh rate It is possible to get DMX refreshes at around 1000 times per secon...

Page 10: ...x3W 6x Each Red Green Blue 100 000 hours Edison Brand Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX C...

Reviews: