Blizzard Lighting Flurry Wash User Manual Download Page 10

Page 19

Flurry Wash Manual Rev. A  

 

 

Copyright (c) 2010 Blizzard Lighting, LLC

Tech Specs!

Weight & Dimensions
Length

6.8 inches (173 mm)

Width

6.8 inches (173 mm)

Height

9.8 inches (249 mm)

Weight

8.3 lbs (3.8 kg)

Power
Operating Voltage

110-230VAC, 50-60 Hertz (selectable via 

voltage switch)

Fuse

2A 250V

Power Consumption

120W

Light Source
LED

18x3W (6x Each Red, Green, Blue), 100,000 

hours, Edison® Brand.

Movement Range
Pan

540 degrees

Tilt

270 degrees

Thermal
Max. Operating Temp. 104 degrees F (40 degrees C) ambient

Control
Protocol

USITT DMX-512

DMX Channels

5 or 13 (User Selectable)

Input

3-pin XLR Male

Output

3-pin XLR Female

Optional Controller

CA-9 Easy Controller

Coolness Factor
Leventy Billion Percent

Warranty

2-year limited warranty, does not cover mal-

function caused by damage to LED’s.

Enjoy your product!  

Our sincerest thanks for your purchase!

--The team @ Blizzard Lighting

Summary of Contents for Flurry Wash

Page 1: ...5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 The Control Panel 10 Control Panel Menu Structure 11 Ad...

Page 2: ...thing Getting A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting 2705 Brookview Ct Brookfield WI 53005 USA support blizzardlighting...

Page 3: ...LED display menu with invert Reset to factory settings option Display auto on off Pan tilt invert option Fan cooled OPTIONAL CONTROLLERS Easy Controller CA 9 DMX Quick Reference 13 Channel Mode Channe...

Page 4: ...apacitance between conductors 30 pF ft Maximum capacitance between conductor shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 8 Flurry Wash Manual Rev A Copyri...

Page 5: ...ting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance Safe...

Page 6: ...the UP DOWN buttons to set to the desired position press ENTER to confirm TO SET THE DMX CHANNEL CONFIGURATION 1 Press the MODE ESC button until it shows or 2 Use the UP DOWN buttons to set to the de...

Page 7: ...act as follows Button What it Does Standby Blackout Function 1st click Strobe On 2nd click Strobe Off Mode 1st click Sound Active Mode Remote LED will be on 2nd click Auto Mode LED will be off DMX Mod...

Page 8: ...ble No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Contact service for more information Chase Speed Too Fast Slow Check to ensure pr...

Page 9: ...to be output per packet and in fact it is very uncommon to find all 512 used The fewer channels are used the higher the refresh rate It is possible to get DMX refreshes at around 1000 times per secon...

Page 10: ...x3W 6x Each Red Green Blue 100 000 hours Edison Brand Movement Range Pan 540 degrees Tilt 270 degrees Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX C...

Reviews: