![Blizzard Lighting Flurry EXA User Manual Download Page 14](http://html1.mh-extra.com/html/blizzard-lighting/flurry-exa/flurry-exa_user-manual_2773071014.webp)
Page 14
Flurry EXA™ Moving Head Wash - Rev. A
(c) 2015 Blizzard Lighting, LLC
DMX Mode
Allows the unit to be controlled by any universal DMX controller.
Set The DMX Starting Address
1.) T
o assign a DMX staring address to the fixture, press the
<ESC>
button
until you reach the top menu level (and then use the
<UP/DOWN>
buttons if
necessary) to navigate to
MENU1: Dmx 11CH,
and press the
<ENTER>
button.
Then use the
<UP/DOWN>
buttons to display any value within the range of
001-
512
, then push the
<ENTER>
button.
Slave Mode
1.)
Connect fixtures together via DMX, then set each fixture to the same starting
DMX address.
2.) The first fixture in the DMX chain is the master fixture, and the following
fixtures will follow the master.
Auto, Stand-Alone, Sound Active Modes:
Allows single or M/S units to run factory installed programs at user selectable speeds.
Auto Mode
1.) Press the
<ESC>
button until you reach the top menu level (and then use the
<UP/DOWN>
buttons if necessary) to navigate to
Menu2: Programs,
and press
the
<ENTER>
button.
2.) Press the
<UP/DOWN>
buttons to highlight
AUTO1-AUTO6
, then press
<ENTER>
.
Sound Active Mode
1.) Press the
<ESC>
button until you reach the top menu level (and then use the
<UP/DOWN>
buttons if necessary) to navigate to
Menu2: Programs,
and press
the
<ENTER>
button.
2.) Press the
<UP/DOWN>
buttons to highlight
Sound
, and then press the
<ENTER>
button.
3.) You can then adjust the mic sensitivity level by returning to the top menu
level, and then in the same manner navigate to
Menu4: Option > Sound
, and
choose a mic level setting between the values of 000-255.
Manual Adjustments
1.) Press the
<ESC>
button until you reach the top menu level (and then use the
<UP/DOWN>
buttons if necessary) to navigate to
Menu3: Manual,
and press
the
<ENTER>
button.
2.) Press the
<UP/DOWN>
buttons to highlight
CH1-CH15
, and then press the
<ENTER>
button.
3.) Every option for
CH1-CH15
uses the exact same values of 000-255 as listed