Cable Connectors

Cables must have a male XLR connector on one end and a female XLR 

connector on the other end.  (Duh!)

CAUTION:

 Do not allow contact between the common and the 

fixture’s chassis ground. Grounding the common can cause a ground 

loop, and your fixture may perform erratically. Test cables with an 

ohm meter to verify correct polarity and to make sure the pins are not 

grounded or shorted to the shield or each other.

3-Pin???  5-Pin???  Huh?!?

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.  

They are widely available over the internet and from specialty retailers.  If you’d like to build your own, 

the chart below details a proper cable conversion:

Conductor

3-Pin Female 

(Output)

5-Pin Male 

(Input)

Ground/Shield

Pin 1

Pin 1

DMX Data (-)

Pin 2

Pin 2

DMX Data (+)

Pin 3

Pin 3

Not Used.

No Connection.

No Connection.

Not Used.

No Connection.

No Connection.

Take It To The Next Level:  Setting Up DMX Control

Step 1: 

Connect the male connector of the 

DMX cable to the female connector (output) 

on the controller.

Step 2:

 Connect the female connector of 

the DMX cable to the first fixture’s male 

connector (input).  

Note:

  It doesn’t matter 

which fixture address is the first one 

connected.  We recommend connecting the 

fixtures in terms of their proximity to the 

controller, rather than connecting the lowest 

fixture number first, and so on.

Step 3:

 Connect other fixtures in the chain 

from output to input as above.  Place a DMX 

terminator on the output of the final fixture 

to ensure best communication.

Summary of Contents for Blockhead II

Page 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2015 tm...

Page 2: ...I Fixtures 8 Data DMX Cables 8 Cable Connectors 9 3 Pin 5 Pin Huh 9 Take It To The Next Level Setting up DMX Control 9 Fixture Linking Master Slave Mode 10 Mounting Rigging 10 4 Operating Adjustments...

Page 3: ...o please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed...

Page 4: ...ervicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at...

Page 5: ...ve 3 pin male input and 3 pin female output PowerCon compatible AC power In Out connectors CONTROL USITT DMX 512 19 29 117 channels 3 pin Input Output 4 button menu with LCD display DMX Quick Referenc...

Page 6: ...15 Section 2 Green Intensity middle square 15 Global White Intensity 0 100 16 Section 2 Blue Intensity middle square 16 LED 1 Red Intensity 17 Section 2 White Intensity middle square 17 LED 1 Green In...

Page 7: ...ting LLC Figure 1 The BlockHead II Pin Up Picture 25x CREE 12w RGBW LEDs 4 Button Control Panel Menu with LCD Display Figure 2 The Rear Connections Artnet Output Fuse Artnet Input DMX Output Head Arms...

Page 8: ...cting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distanc...

Page 9: ...like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No...

Page 10: ...the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Page 11: ...NU button to scroll through the various top level options then and press ENTER Then to scroll through sub menu options use the UP DOWN buttons Push the ENTER button to save any changes made Control Pa...

Page 12: ...e Slave Mode 1 Disconnect fixture s from any DMX signal source 2 Set each fixture to matching DMX modes 19 29 or 117 3 For each fixture you want to run in slave mode use the menu button to navigate to...

Page 13: ...G11 64 B14 77 W17 90 R21 103 G24 13 W1 26 R5 39 G8 52 B11 65 W14 78 R18 91 G21 104 B24 14 R2 27 G5 40 B8 53 W11 66 R15 79 G18 92 B21 105 W24 15 G2 28 B5 41 W8 54 R12 67 G15 80 B18 93 W21 106 R25 16 B...

Page 14: ...179 180 188 189 197 198 206 207 215 216 224 225 233 234 255 Static Pattern Effects Static Pattern 1 Static Pattern 2 Static Pattern 3 Static Pattern 4 Static Pattern 5 Static Pattern 6 Static Pattern...

Page 15: ...075 099 100 124 125 149 150 199 200 255 Macro Function Control No Function Numbers Symbols and Patterns control with channel 110 Letters control with channel 111 Static Pattern Effects control with ch...

Page 16: ...ection 3 Green Intensity center LED 20 000 255 Section 3 Blue Intensity center LED 21 000 255 Section 3 White Intensity center LED 22 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 06...

Page 17: ...Static Pattern 18 Static Pattern 19 Static Pattern 20 Static Pattern 21 Static Pattern 22 Static Pattern 23 Static Pattern 24 Static Pattern 25 Static Pattern 26 Cycle all channel 27 controls speed 2...

Page 18: ...te Pan No function Continuous Rotating CW Continuous Rotating CCW 3 000 255 Tilt 0 540 degree 4 000 055 056 155 156 255 Infinite Tilt No function Continuous Rotating CW Continuous Rotating CCW 5 000 2...

Page 19: ...161 162 170 171 179 180 188 189 197 198 206 207 215 216 224 225 233 234 255 Static Pattern Effects Static Pattern 1 Static Pattern 2 Static Pattern 3 Static Pattern 4 Static Pattern 5 Static Pattern...

Page 20: ...X covers and is an abbreviation for Digital MultipleXed signals It is the most common communications standard used by lighting and related stage equipment DMX provides up to 512 control channels per d...

Page 21: ...send an email to support blizzardlighting com and we ll issue you an RA Then you ll need to send the unit to us using a trackable pre paid freight method We suggest using USPS Priority or UPS Make su...

Page 22: ...ITT DMX 512 DMX Channels 19 29 117 Channels Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Auto Sound Active Other Information Helen Hunt but only when Hele...

Page 23: ...zzard Lighting LLC Luminous Intensity Lux Meter 1 Meter 2 Meter Red 22 100 Lux 8 900 Lux Green 20 200 Lux 9 300 Lux Blue 23 700 Lux 10 400 Lux White 30 900 Lux 13 600 Lux All 89 600 Lux 37 600 Lux Dim...

Page 24: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Reviews: