Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 10 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2200-SI_J1939_UM_REV1.0
16.
Event state transmission (72h)
This message enables or disables event driven key state transmissions. When this feature is
enabled, the keypad transmits the state of a contact at the time that the contact changes state
(pressed or released).
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
72h
Event state transmission
Byte 3
XXh
XX:
00h Disabled
01h Enabled (default)
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format Message
Data
To
Keypad
18EF2100h Ext
04 1B 72 00 FF FF FF
FF
Disable event state
transmission
17.
LED Acknowledgment (73h)
This message enables or disables the transmission of the LED Acknowledgement message.
When this feature is enabled the keypad transmits an acknowledgement message each time a
LED Command is received.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
73h
LED Acknowledgement
Byte 3
XXh
XX:
00h Disabled (default)
01h Enabled
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format Message
Data
To Keypad
18EF2100h Ext
04 1B 73 01 FF FF FF
FF
Enable LED
acknowledgement
To Keypad
18EF2100h Ext
04 1B 01 01 04 03 05
FF
LED Command
From
Keypad
18EFFF21h Ext
00 03 01 04 05 FF FF
FF
LED Ack message
LED Acknowledgement message:
Byte 0
00h
Byte 1
XXh
XX: LED state
Byte 2
YYh
YY: LED number
Byte 3
PPh
PP: Primary color
Byte 4
ZZh
ZZ: Secondary color
Byte 5,7
FFh
Not used