Main Power GFI Breaker
– this industrial grade GFI (ground fault interrupting) breaker is the connection point for main power cables connected to
the panel. Consult your local codes to determine if you can utilize this breaker as a main disconnect as well. In any case, we highly recommend a
suitable disconnect switch be installed prior to the panel for safe servicing of the panel. Your contractor will need to punch a hole in your panel for the
main power cable conduit in your desired location. Power demand for the brewhouse is 150A at 240V (single phase). Select a main breaker setting
for 20% above the appropriate amperage to avoid nuisance tripping or as directed by your local codes.
RTD’s
– the brewhouse is equipped with two durable high precision PT100 temperature probes. The sensors come prewired to your controler panel.