WIRELESS SMART THERMOSTAT
control with μWiFi technology
from any place in the World
SAFETY RULES
Do not connect the device to loads exceeding the permitted
values.
Connect only in accordance with the diagram presented in the
manual. Improper connections may be dangerous, it can damage
the controller, and loss of the warranty.
DANGER! Risk of electric shock! Even with the device turned off,
the outputs may be live. All assembly work should be ALWAYS
performed with the disconnected power circuit.
The installation of the device to a power mains that does not
meet the quality requirements defined by PN-EN 50160, will
result in the loss of the warranty.
To ensure protection against electric shock, the protective
terminal of a I class devices must always be connected to the
protective earth (PE) therminal in the TN-S network or to the
neutral-protective (PEN) therminal in the TN-C network. At the
instalation of electrical devices, special attention must be paid to
the protection against electric shock described in PN-HD
60364-4-41.
Protect the power circuit with overcurrent protection in B
characteristic and rated current up to 16A.
Connection of the controller must be carried out only by persons
with the corresponding electrician license.
1
INSTALLATION - BASICS
Disconnect the installation supply voltage before installing the controller.
Remember that any mounting works should be carried out when the mains
voltage is disconnected (switch off the mains fuse or disconnect the power
cord from the mains socket).
The controller should be installed in a place protected against adverse
environmental conditions, protected from third party access - in the flush box
or inside the enclosure of the controlled device. Remember that metallic
elements (wires, housing parts) have a negative influence on the range of the
device, and consequently the comfort of use. It is recommended that the
device be mounted in a stable and fixed position. Due to the operating
voltage of the device it is necessary that the connectors of the controller be
protected against accidental contacts or short circuits, which could cause
electric shock or damage to the device.
A digital probe was used to measure the temperature, which should be
placed inside the heated / cooled room according to the recommendations in
the diagrams. The final decision on the choice of probe location is made by
the installer. It is not recommended to extend the original temperature probe
cable excessively since the induced interference can cause the controller
malfunction or even damage it.
The controller is designed to work with an additional safety sensor whose
task is to limit the heating of the surface contiguous to the heaters (e.g.
wooden floor) during heating or freezing (e.g. evaporator) during cooling.
The maximum (minimum) safe temperature is selected in the controller
settings during configuration. The controller will regulate heating / cooling
so as not to exceed the safe surface temperature (measured with the safety
probe) while reaching the set temperature. The main probe provides readout
of the current room temperature for regulation.
After making sure that the device is connected in accordance with the
diagram and that there are no metal components near the controllerwhich
may accidentally cause short-circuit, start the device by turning on the power
(turning on the mains fuse or connecting the power cord to the power
outlet).
Read the diagram and then proceed to install the controller. Pay particular
attention to the designation of the controller connectors. Start with power
wires - phase L (usuallybrown) and neutral N (blue). Then, connect the load.
Remember to connect the protective wire PE (yellow-green). If you only want
a local control with a wall switch, connect the wall push-button according to
the diagram. To control using only your phone or Tablet, it is not necessary to
install the wall push-button.
Connect the external temperature probe to the blue connector in the order of
colors (from top): black, red and yellow or white, brown and green. If an
additional safety probe is also installed, it must be connected in parallel to the
main probe.