Appliances operated with NG (natural gas) gas must be installed with the NG regulator supplied with the
unit and set to 4.0" water column pressure.
•
Appliances operated with LP (liquid propane) gas must be installed with an LP regulator set to 11" water
column pressure.
•
Please contact your dealer and use a licensed contractor or installer to convert your appliance to the
different gas type.
•
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN CONTACT WITH ANY
HOT SURFACE, SHARP OR ROUGH EDGES OF THE APPLIANCE OR OUTDOOR KITCHEN
CONSTRUCTION. DO NOT KINK THE GAS LINE WHEN INSTALLING.
The self-contained LP system appliance is design certified to be used with a standard 20 lb., 12 1/4" diameter; 18"
high cylinder with right handed connection threads and this is the maximum size LP tank to be used. The cylinder
must be marked in accordance with the latest U.S. Department of Transportation specifications for LP gas
cylinders. (DOT. CFR49 or National Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods a Propane Tank with an ODP Overfill Prevention Device must be used at all
times.)
IMPORTANT: Never connect the appliance to an unregulated gas supply.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must
conform with local codes or in the absence of local codes, to the National Fuel Gas Code, ANSI Z223.1/NFPA
54 and Natural Gas Installation Code, CSA B149.1. All Natural Gas installations must conform to local codes or
in the absence of local codes the national fuel gas code, ANSIZ2223.1a-
‐
1998.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must conform
with local codes or, in the absence of local codes, with Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2 as applicable.
Installation in Canada must be in accordance with the standard CAN/CGA- B149.2.
A licensed contractor or local gas company representative must perform all gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the
appliance and giving ease of access.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system.