OM-SC25 E V1.04
July 11, 2016
Page 11
SC25
INSTALLATION INSTRUCTIONS
•
BEFORE INSTALLING THIS APPLIANCE, CONTACT THE LOCAL BUILDING OR FIRE OR OTHER
AUTHORITY HAVING JURISDICTION AND FOLLOW THEIR GUIDELINES.
•
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. FOLLOW THE
INSTALLATION DIRECTIONS. DO NOT OPERATE WITHOUT FULLY ASSEMBLING ALL
COMPONENTS.
•
IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT.
•
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF
CONTACTED. CHILDREN AND PETS MUST BE KEPT FROM TOUCHING THE APPLIANCE
WHEN IT IS HOT.
•
COMBUSTIBLE MATERIAL SUCH AS FIRE WOOD, WET CLOTHING, ETC. PLACED TOO CLOSE
CAN CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A
MINIMUM OF 48”(1219 MM) FROM THE FRONT OF THE APPLIANCE.
Blaze King grants no warranty, implied or
stated, for the installation or maintenance of the
appliance and assumes no responsibility of any
consequential damage(s).
PARTS INCLUDED WITH THE SIROCCO 25 INSERT
1. Poker
2. Manual kit (w/ warranty cards, fi re starter, labels)
3. Bypass handle (Z2052)
4. Part #Z2015 fl ue collar assembly with gasket (attached to #225.2054 6” fl ex fl ue
adapter)
5. Part #225.2054 6” fl ex fl ue adapter
FLOOR PROTECTION
If the bottom of the appliance is 5” (125 mm) or more above the fl oor level only ember protection is required
(UL 1618 type 1) extending 16” (407 mm) in USA or 18” (458 mm) in Canada in front of the door and extending
8” to either side of the door opening.
If the bottom of the appliance is at fl oor level or less than 5” (125 mm) above fl oor level, a layer of non-
combustible thermal protection (UL 1618 type 2) where R=1.06 is required under the appliance extending 16”
(407 mm) in the USA and 18” (458 mm) in Canada.
COMPONENTS REQUIRED
6” stainless steel liner - listed to: UL 1777, ULCS35 OR ULCS640, and part #225.2054 fl ue extension.