180-CL29-SP v1.00
March 12, 2019
Page 14
Clarity CL29 SP
OPERATING INSTRUCTIONS
PILOT LIGHT
Refer to the lighting instruction label on how to light
the pilot. Check that the pilot has fully engulfed the
thermocouple assembly (
Fig.1
).
LIGHTING THE BURNER
Standing Pilot (SP)
The CLARITY CL29 SP controls are located behind
the hinged fl ap beneath the fi rebox.(
Fig.2
) To light
the burner follow the steps below:
1.
Make sure the pilot is lit (see “LIGHTING
INSTRUCTIONS Standing Pilot”)
2.
Turn the “
Valve Control
” knob counterclockwise
to ON.
3.
Flip the fl ame ON/OFF switch, located beside the
igniter to ON.(
Fig.2
)
4.
Turn the “
Flame Height
” knob to the desired
fl ame height.(
Fig.2
)
5.
Turn on all electrical power to the unit.
6.
NOTE
: Burn the appliance on high, with the
optional blower OFF, for the fi rst two to three
hours. This will cure all the paint, gasket, and
seals. It is advised to open a door or window
as the unit will smoke and give off odors as it is
curing.
OPTIONAL BLOWER
An optional blower S.Z4946.SP is available. For
installation refer to the installation instructions
provided with the kit.
Turn the blower on by turning the “
Blower Speed
”
knob clockwise
.(
Fig.2
) The blower will only
come on when the fi replace is up to temperature
(approximately 10-15 minutes) because it is equipped
with a thermal switch. Fan speed control sequence
is off , then maximum to minimum. The speed of the
fan can be decreased by turning the knob clockwise
. The speed of the fan can be increased by
turning the knob counterclockwise
. The blower
will continue to operate after the burner is turned off
(approximately 15-20 minutes). To turn the blower off
manually, turn the fan control knob counterclockwise
until it “clicks”.
Fig.2
Fig.1