Installation—Location & Clearances

 

YOUR STOVE'S LOCATION  

 
1.  Your stove should be centrally located in the area to be heated. It should be placed away from 

doors and hallways and out of the line of traffic as much as possible. Plan ahead to be certain that 
furniture, drapes and curtains cannot come within the combustible clearances listed on the table 
below.  

2.  This stove must be connected to a chimney that is vented to the outside. Never permit your stove to 

vent into any room of the building.  

3.  Check the attic or space above the ceiling, or behind walls through which you intend to run your 

stove pipe and chimney,  to assure there are no existing heating ducts, electrical wiring, conduit, or 
major structural support beams in the way. A straight stove pipe is best.  

4.  Consult illustrations in the back of this manual to ensure that you install your stove the proper 

minimum distances from combustible materials.  

 

FLOOR PROTECTION 

 

Floor protection may be any non-combustible material or Listed Floor Protector.  In the USA It must 
extend at least 18” in front of the loading door opening and 8 inches beyond the sides of the door 
opening. In Canada 18” in front  and 8 inches beyond the side and inline with the rear of the stove.  In 
certain installations floor protection must be provided under the chimney connector and 2 inches 
beyond each side of the chimney connector.  Position the floor protector so that no floor ducts are 
covered.  
 

CLEARANCES TO COMBUSTIBLE MATERIALS 

** Mobile Home and Alcove Installations must use double wall listed pipe, side shields and rear shield. 
Mobile Home Installations require Outside Combustion Air Kit # Z1526.

 

 

Residential Installations 

 

Single Wall Pipe (24 MSG Black) 

15” / 381 mm 

15” / 381 mm  25.75” / 654 mm  18” / 457 mm  15” / 381 mm 

Listed Double Wall Pipe—Close Clearances 

Use side shields and  rear shield. 

(Must use for Mobile / Manufactured 
Home Installations, Alcove Installation 
and Close Clearance Installations)

 

14” / 356 mm 

8” / 203 mm  24.75” / 629 mm  11” / 279 mm 

8” / 203 mm 

Summary of Contents for BRIARWOD BRII/90

Page 1: ...THESE INSTRUCTIONS FOR FUTURE REFERENCE LISTED BY Valley Comfort Systems Inc 1290 Commercial Way Penticton BC V2A 3H5 CANADA Phone 250 493 7444 Fax 250 493 5833 Blaze King Industries 146 A Street Walla Walla WA 99362 U S A Phone 509 522 2730 Fax 509 522 9803 Manufactured By Blaze King Pour la version française de nos manuels S V P vous référez à notre site web www blazeking com ...

Page 2: ...by a qualified licensed installer have it checked by your local inspector Disregarding inspection and code requirements may jeopardize your homeowner s insurance Since some insurance carriers require notification of a stove installation you should contact your insurance agent We want your stove to give you many years of trouble free operation While we have made every effort to make these instructi...

Page 3: ...imney Draft 14 Chimney height 14 Chimney requirements 14 Chimney Installation Masonry Chimney 15 Mobile Home Installation Instructions 16 Grounding 16 Chimney Height 16 Outside Air 16 Floor Protection 16 Attaching Stove to Floor 16 Operation 17 Grates 17 First Fire 17 Curing Paint 17 Starting Fire 17 Controls 17 Do Not Burn 17 Heat Output 17 Do Not Over fire 17 Accessories Installation Fan Kit and...

Page 4: ...owner End User except as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitations listed 2 Years X Fan assemblies and motors thermal sen sors catalytic thermometer bi metallic thermostat assembly 5 Years 2 Year X Firebox Heat Exchanger Bypass Door Steel Compo...

Page 5: ...aser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer on any oral warranty or representation All claims under this Limited Warranty must be made in writing by your dealer 2 Any stove or part thereof that i...

Page 6: ...environmental conditions Environmental conditions include but are not limited to nearby trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 11 The Limited Warranty does not cover damage caused by burning salt saturated wood corrosive driftw...

Page 7: ...King to be non warrantable Blaze King is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 26 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once ...

Page 8: ...TIBLES See owners manual for complete description of all requirements Mobile Home and Alcove Installations must use double wall listed pipe side shields and rear shield Mobile Home Installations require Outside Combustion Air Kit Z1526 Floor protection may be any non combustible material or Listed Floor Protector and must extend at least 18 406 mm in front of the loading door opening Minimum size ...

Page 9: ...ST HOME FIRES CAUSED BY WOODBURNING STOVES ARE THE RESULT OF IMPROPER INSTALLATION AND OPERATION READ ALL INSTRUCTIONS THOROUGHLY BEFORE INSTALLING AND OPERATING YOUR Briarwood II STOVE SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS 1 CONSULT YOUR LOCAL BUILDING INSPECTOR TO ENSURE YOUR INSTALLATION COMPLIES WITH BUILDING AND FIRE CODES 2 Design your installation with safety as the primary considerati...

Page 10: ...ely obtain a copy of the National Fire Protection Association publication Using Coal and Wood stoves Safely NFPA Number HS 6 1974 The address of the NFPA is 470 Atlantic Avenue Boston MA 02210 24 For further information refer to NFPA 211 25 Do not over fire your woodstove Although the Briarwood II is designed to heat efficiently it should never be fired to a red hot condition 26 CHIMNEY CONNECTOR ...

Page 11: ...closed container of ashes should be placed on a non combustible material pending final disposal Once they are cooled they can be disposed of by burial in soil or other suitable methods WET OR GREEN FUEL Wet or green fuel should not be used Wood should be cut into pieces and allowed to air dry for several months before you attempt to burn it After the wood supply is cured dry ensure it is protected...

Page 12: ...er minimum distances from combustible materials FLOOR PROTECTION Floor protection may be any non combustible material or Listed Floor Protector In the USA It must extend at least 18 in front of the loading door opening and 8 inches beyond the sides of the door opening In Canada 18 in front and 8 inches beyond the side and inline with the rear of the stove In certain installations floor protection ...

Page 13: ...e on your stove 3 If you are installing a new chimney follow the manufacturer s installation instructions very carefully Be sure to comply with all safety recommendations Use only insulated pipe and components with approved shields to pass through combustible walls and ceilings 4 Make a mark on the floor around each corner of the heater Move the stove and install the floor protector Be sure to ext...

Page 14: ...ney installations Listed solid fuel chimney liners are required for masonry installations in Canada Mobile home units require certain listed components and chimney manufacturers See Mobile Home Instructions page 16 for details Refer to the chimney and chimney connector manufacturer s instructions for additional information If this stove and its chimney components are not properly installed a house...

Page 15: ...eed three feet NOTE THE CONNECTOR MUST SLOPE UPWARD TOWARD THE CHIMNEY AT THE RATE OF 1 4 PER FOOT This slope in the horizontal connection is required to encourage the water vapor to drain back into the stove Use a carpenter s level and a ruler or tape measure to check the slope Under no condition should the chimney connector have more than one 90 degree bend or two 45 degree bends The distance be...

Page 16: ... of the stove Always use a star lock washer to ensure a good electrical connection between the ground wire and the stove CHIMNEY HEIGHT The chimney system must have a section joint so that any parts extending over 13 feet 6 inches above ground level can be removed when transporting the mobile structure Care must be taken when dissembling so no hidden joints are loosened to allow flue emissions to ...

Page 17: ...d 6 You may now place several larger pieces of wood on the fire In order to insure complete combustion of the organic compounds released from the wood load the fuel as far back in the firebox as possible The charcoal bed can be sloped slightly towards the rear so that the fuel does not tend to fall forward Close the door with the draft control open until a robust fire occurs 7 Clean away any coals...

Page 18: ...n the stove top B Attach the rear heat shield through the shield and into the back of the stove with 4 bolts C Position the fan kit on the rear heat shield The mounting holes are pre punched and located near the bottom Attach using four 10 sheet metal screws USE CARE WHEN ROUTING THE POWER CORD MAKE SURE IT IS NOT UNDERNEATH THE BASE OF THE STOVE Fan Kit Electrical Diagram Rheostat Green Ground Sc...

Reviews: