PAGE 10
OM-9603
Date Printed: February 15, 2008
Version: 1.02
UNIT MUST BE SECURED TO THE FLOOR .
A separate ground wire must be run from the unit to the frame of mobile home. Use a copper lug w/tab and
attach to the hole in the right rear of the pedestal.
A manufactured home (mobile home) installation must conform with the Manufactured Home construction and
Safety Standard, Title 24 CFR, Part 3280.
When such a standard is not applicable, the Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A.
MOBILE HOME INSTALLATION
As you plan your installation consider the following:
The stove should be placed in the home as centrally as possible. Consider safety, convenience, traffic flow. You
must also considered where you will be venting the appliance.
DUE TO HIGH TEMPERATURE THE ROOM HEATER SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY
FROM FURNITURE AND DRAPERIES.
MINIMUM CLEARANCES SHOWN ON PAGES 26-27 ARE TO
PREVENT WALLS AND CEILINGS FROM CATCHING ON FIRE.
For the type of vent system to be used, see pages 15-23.
Electrical Power is 115-60HZ SEE PAGE 34 FOR
TERMINATION CHART
WARNING
ONLY PERSONS LICENSED TO WORK WITH GAS PIPING MAY MAKE THE NECESSARY GAS
CONNECTION TO THIS APPLIANCE. BE SURE GAS PLUMBING INSTRUCTIONS AND ALL STATE AND
LOCAL CODES ARE CAREFULLY FOLLOWED.
USE APPROVED FLEXIBLE GAS CONNECTIONS OR
RIDGED PIPING, TO ATTACH BURNER TO GAS SUPPLY, DEPENDING ON STATE OR PROVINCIAL AND
LOCAL CODES .
BE SURE TO USE PROPER SIZE GAS SUPPLY LINE.
CAREFULLY CHECK ALL
CONNECTIONS WITH SOAP AND WATER SOLUTION FOR GAS LEAKS .
NOTE: DO NOT CHECK FOR LEAKS USING AN OPEN FLAME.
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code
,
ANSI Z223.1/NFPA 54
, or the
Natural Gas and Propane Installation Code, CSA B149.4.
A manufactured home (USA only) installation must conform with the
Manufactured Home Construction and Safety Standard,
Title 24 CF
R,
Part 3280
, or, when such a standard is not applicable, the Standard for
Manufactured Home Installation, ANSI/
NCSBCS A225.1
, or Standard for
Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
PLANNING YOUR STOVE PLACEMENT
WARNING - The appliance, when installed must be electrically grounded in accordance with
local codes or in the absence of local codes with the National Electrical Code ANSI/NFPA 70-
1987. Or the current Canadian Electrical Code - CSA.C22.1
ELECTRICAL GROUNDING INSTRUCTIONS
The power cord on this unit will have a Green wire with a ring (eye) connector on the end of it.
This has to be attached to a green screw located on the bottom right of where the fan assembly rests.
CLEANING YOUR PEGASUS 9603
Your appliance was designed with very low maintenance in mind. At the end of the heating season simply turn
the control knob on the gas valve to the “OFF” position. Allow the unit to cool off completely remove logs and
embers. Vacuum all accessible portions of the unit, including inside of the fire box. Replace logs and embers.
NOTE: THERE ARE NO PARTS THAT REQUIRE LUBRICATION ON THIS STOVE