The Tuscany
by Blaze King
Owners Installation and Operation Manual
OM-6003T
Page 23
DATE PRINTED: 4/3/14
Version 1.10 SIT
120 VOLT CIRCUIT
Snap Disc
F130
MILLIVOLT CIRCUIT
Cordset
Ground
Blower Control
#0136
Blower #0719B
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
Wiring Diagrams
THIS MOBILE/MANUFACTURED HOME APPROVED APPLIANCE MUST BE GROUNDED TO THE STEEL
CHASSIS OF THE HOME. USE AN 8 GAUGE COPPER WIRE AND A SERRATED OR STAR WASHER TO
PENETRATE PAINT OR PROTECTIVE COATING TO ENSURE GROUNDING.
Pilot Assembly #Z6003
Thermocouple
Thermopile
Pilot Gas Line
Thermostat leads or leads to
optional remote thermostat
Thermostat
On/Off Rocker
Switch #0725
TH
THTP
TP
SIT Gas Valve #SIT0820652
TH
TP
TP-TH