The Tuscany
by Blaze King
Owners Installation and Operation Manual
OM-6003T
Page 16
DATE PRINTED: 4/3/14
Version 1.10 SIT
Vent Restrictors
Due to the extra flow
produced by certain
venting configurations
vent restrictors must be
placed in the vent to
maintain performance.
The vent restrictors
come in four sizes.
When your installation
r e q u i r e s a v e n t
restrictor the correct
restrictor is placed
inside the vent adaptor
collar on the unit.
Proper instructions for
installing a vent
restrictor are included
in the vent restrictor kit.
4” Collar attached
Adaptor
Before sliding the pipe into the termination ensure that you
slide the decorative wall thimble cover and penetration heat
shield over the pipe.
Slide the pipe into the vent, making sure there is at least 1”
overlap between the pipe and the terminal. Attach the pipe by
attaching two sheet metal screws through the termination
straps and into the pipe. Bend back the straps towards the
termination cap making sure they are hidden by the
decorative thimble. Finally attach the wall penetration heat
shield and secure with wood screws.
HOT
Vertical Installations
Always maintain the 1” clearance around the vent pipe
(vertical), when passing through ceilings, walls, roofs,
enclosures, attic rafters or any combustible surfaces.
DO NOT PACK AIR SPACES WITH INSULATION.
Refer to the vent chart for maximum allowable vertical and
horizontal installations.
When planning your installation determine if ceiling joists, roof
rafters or other framing will obstruct the vent system. You may
have to use 45° elbows to navigate around any obstacles.
When passing through a flat ceiling install a Box/Wall thimble.
Cut a 10” square hole and frame as shown in the diagram
opposite.
Ensure all pipe sections are fully twist locked.
Basement Installations
To achieve the minimum vertical rise a 36” snorkel may be used.
Where the bottom of the terminal may be blocked by snow etc
ensure provision is made for adequate drainage.
Drainage
Minimum 12”
NOTE: ALWAYS CHECK YOUR LOCAL CODES
BEFORE INSTALLING VENTING. NECESSARY
CLEARANCES AND REQUIRMENTS MAY VARY
FROM STATE TO STATE(PROVINCE TO
PROVINCE).
Installation Instructions
Restrictor Sizes