background image

 

19 

 

 

 

/- 

D/-

 allows you to add/remove /edit devices. The functions include: 

Add Devices 

Edit Devices 

Remove Devices 

Learn PSS 

 

Add Devices

 

1. 

To learn in a device, select 

Add Device

, press “

OK

” to confirm. 

2.

 Press the test /learn button on the device, refer to device manual for detail. 

3.

 If a signal is detected, the screen will display the device information, press “

OK

” to confirm. 

    

If the device already exists in system, the screen will display “

Already exist in system

”: 

4.

 Select the Zone number for the device, press “

OK

” to confirm. 

5.

 For Door Contact, PIR sensor, and EIR sensor, you need to select one of the three attributes for 

the device, available attributes include: 

 

Burglar

 (

B

When  the device is triggered under Away Arm or Home Arm mode, a Burglar Alarm will be 
activated immediately.  

When the device is triggered during Entry or Exit countdown, the alarm will not be activated. 

 

Home Omit

 (

O

When the device is triggered under Away Arm mode, a Burglar Alarm will be activated 
immediately. 

When the device is triggered under Home Arm mode, the alarm will not be activated. 

 

Entry

 (

E

When the system is in any Arm mode, if an “

Entry

” device is triggered, the Control Panel will 

start an Entry Delay countdown timer for the user to disarm the system. 

After the delay period has expired and no correct PIN code has been entered, the Control 
Panel will activate iren immediately to remind the user the delay period has expired. 

If the Control Panel is not disarmed within 30 seconds after the delay period expires, a 

Burglar 

Alarm

 will be reported. Disarming the Control Panel within the 30 second period will return the 

system to Disarm mode and silence the siren. No alarm will be reported. 

When the system is in Disarm mode, if a  “

Entry

”  is  triggered, the Control Panel will make a 

ding-dong

” Door Chime sound (if Door Chime function is not disabled). 

6.

 Enter a name for the device, press “

OK

” to confirm. You can also leave the name blank. 

7.

 The screen will display the final device information, press “

OK

” to confirm and complete learning 

for the device 

The device types are identified by the following abbreviation in the system: 

 

Door Contact ---- DC 

 

PIR Sensor  ----- IR 

Summary of Contents for SA 2700

Page 1: ...SA 2700 Kit User Manual ...

Page 2: ...u __________________________________________________________12 7 Programming Mode __________________________________________________14 8 Operation___________________________________________________________22 9 Connect2Home Application____________________________________________26 10 Troubleshooting Factory Reset ______________________________________27 11 Specifications ___________________________...

Page 3: ......

Page 4: ...d or removed from mounted surface When the tamper switch is triggered the alarm system will be activated to inform you To make sure the tamper switch functions properly please make sure the switch is fully depressed against the mounting surface when installing your Control Panel or devices System Extension Aside from the devices included in the package you can further improve the capability of you...

Page 5: ...nal transmitted simutaneously from PIR and Door Contact could cancel each other Do not mount the PIR sensor directly exposed to sunlight Do not point PIR sensor at window or sources of heat e g fire or boiler Control Panel The Control Panel should be mounted in a hidden area and invisible however still accessible The Control Panel should be mounted at a location with good GSM strength to send repo...

Page 6: ...N code is disabled insert the SIM card into a working mobile phone go to SIM card PIN code setting in mobile phone setting functions to disable the SIM card PIN code 3 If a prepaid SIM card is used please check the SIM card information carefully as each SIM card provider has their own policy Some SIM cards have a validity period and must be extended before they expires some SIM cards will expire a...

Page 7: ...mes to discharge 3 Insert the new batteries and replace the cover Door Contact The Door Contact detects door window opening and notifies the Control Panel to raise alarm The Door Contact is powered by 2 1 5V AAA alkaline batteries pre inserted by factory Pull out the plastic battery saver tab on the back of Door Contact This will activate the batteries Press the learn button to transmit learn code...

Page 8: ...u have triggered an entry Door Contact or PIR sensor The Remote Controller is powered by a CR2032 3V lithium coin cell which is included in the package Open the back battery cover to insert the battery then replace the cover When the battery voltage runs low slide open the battery cover to change new battery Arm Button Disarm Button Home Button Emergency Button Battery Cover LED Indicator ...

Page 9: ...ort event to then press OK to confirm 4 NOTE The First Time Setup process is only availble when you power on the Control Panel for the first time Once the process is completed it will not appear again All of the options can be changed later again do not worry if you make any mistakes Detail system setting can be done later by accessing the Programming Mode 3 s t e p s e a s y s e t u p O K S e t D...

Page 10: ...f the First Time Setup process 6 First Time Setup process is now complete please see next chapter for device mounting instruction NOTE If no devices are included in the Control Panel When you choose Exit Setup the LCD will display Please add at least 1 device You can either press the learn test button on devices to add them or press Disarm key enter you PIN code then press OK to exit the setup pro...

Page 11: ...ce manual for learn test button location and detail If the device is within range of the Control Panel the screen will display the device information accordingly When you are certain the device can function properly at chosen location proceed to mount the device When mounting devices make sure the device tamper is fully depressed please refer to device manual for tamper location Control Panel The ...

Page 12: ...r side knockouts are for corner mounting Figure 1 1 Break through the knockouts use the knockouts to mark position on wall or corner Figure 2 Figure 1 Figures 2 Wall Corner 2 Drill holes into the wall or corner using the knockouts as template insert wall plug if required Figure 3 3 Screw the PIR Sensor base onto the wall or corner at marked location Figure 4 Then replace the PIR Sensor cover onto ...

Page 13: ... front cover 4 The Door Contact has rib mark on the side that marks location of magnetic switch Figure 5 Use the rib mark to align the magnet and screw the magnet on to the door window Figure 6 The distance between the magnet and Door Contact should be no more than 0 6 inch Figure 4 Figure 5 Figure 6 Alternatively you can also use the double side adhesive tape to install the Door Contact After fin...

Page 14: ...upon connection or send an SMS message Address Message The Address Message will be played in the beginning of all your voice message reports to notify the recipient your user information Please make sure to record your own Address Message by referring to Programming Mode Default Address Message is Alarm System Alarm Length Default alarm length for siren upon activation is set to 3 minutes To chang...

Page 15: ...option will become available only when fault event exists in system to view the fault events 1 Use Up and Down key to scroll through the screen and view fault event 2 Press key to leave you will be asked whether you want to clear fault display 3 If you have rectified the fault press OK to return to Alarm Off mode and the fault event will be removed Unresolved fault event cannot be removed If you w...

Page 16: ...Signal function to check the Control Panel GSM signal strength at current location The signal strength will be displayed in RSSI scale from 0 9 In order for the Control Panel to send and receive report command successfully please make sure the RSSI value does not drop below 5 at installed location If the value drops below 5 the Control Panel may not be able to send report and receive command succe...

Page 17: ...l receives the signal the screen will display device type zone number attribute name signal strength in 0 9 scale accordingly Tel Setting Tel Setting is for you to set edit telephone numbers for sending reports and record Address Message The following items can be selected Tel Numbers Record Msg Test report Tel Numbers Use the function to set change delete the emergency telephone numbers A maximum...

Page 18: ... message the display will ask you to confirm if you want to change the message press OK to confirm 2 After 2 seconds the Control Panel will sound one beep you can now start to record the message 3 Speak clearly and slowly for the Control Panel to record your address When you finish recording press OK to stop recording the recording will automatically stop when it reaches 10 second Test Report This...

Page 19: ...r to the following table b Master Code The Master Code is used to access the Programming Mode for system setting To change the Master Code enter the new 4 digit code and press OK Master Code factory default is set as 1111 c Entry Time When a Door Contact DC PIR Detector IR or External PIR Detector EIR set to Entry attribute is triggered when the system is under Away Arm or Home Arm mode the system...

Page 20: ...ng Special setting provides more function for detail system configuration The items available include the following see a to h a Alarm Length This is for you to select the time length siren should sound when an alarm is activated Options available are 1 15 minute in 1 minute increment 3 minutes is set as factory default b Exit Sound This is for you to decide whether the Control Panel should sound ...

Page 21: ... a SMS report will be sent to programmed telephone number You can set the temperature within the range of 10 C to 50 C When entering temperature value press Up key to select negative value Down key to select positive value When the temperature drops to 3 C below the threshold a SMS report will be sent to programmed telephone number to notify the recipient of High Temperature Restoration You can se...

Page 22: ...ated immediately When the device is triggered under Home Arm mode the alarm will not be activated Entry E When the system is in any Arm mode if an Entry device is triggered the Control Panel will start an Entry Delay countdown timer for the user to disarm the system After the delay period has expired and no correct PIN code has been entered the Control Panel will activate iren immediately to remin...

Page 23: ...r Switch Channel you desire press OK to confirm 3 Select the device you want to edit press OK to confirm the Control Panel will transmit signal to Power Switch 4 The Power Switch LED will flash 3 times upon receiving signal from Control Panel the learning is now complete Learn RP Optional Repeater Required This function is used to learn in Repeater only 1 Put the Repeater into Learning Mode refer ...

Page 24: ...t the GSM if the Panel has GSM related fault conditions to try to solve the problem 1 When you select the function the screen will display Please wait Do not touch the Control Panel during the GSM reset process 2 When GSM reset is complete the screen will return to Programming Mode ...

Page 25: ...he Exit Timer will be reset and start counting from the beginning Home Arm Home Arm will partially arm the system and allows free movement inside the house Arming the System in Home Mode When the system is under Disarm mode 1 Press the Home key on the Control Panel or Remote Controller Remote Keypad 2 The Exit Timer will be displayed and begin to count down according to system setting 3 When the E...

Page 26: ...ntroller press Disarm key Alarm Activation When a device set to Burglar is triggered the alarm will be activated immediately When a device set to Entry is triggered the Entry countdown timer will be activated If the system is not disarmed before the timer expires an alarm will be activated When a device set to Home Omit is triggered in Home Arm mode the device will be ignored If the device is trig...

Page 27: ...e report telephone number and play Burglar message upon answer When the system is under Home or Disarm mode if a tamper switch is triggered the Control Panel will not make any report or activate alarm The fault LED will light up and a fault event will be registered in the Control Panel Dialling and Call Acknowledgement When an alarm is activated the Control Panel will dial the programmed telephone...

Page 28: ...ntrol Panel will hang up The Control Panel will continue Alarming The Control Panel will dial the next number Press 9 The Control Panel will hang up The Control Panel will stop alarming and stop dialling The panel will also stop reporting if 2 call recipients pressed 1 or 0 to acknowledge the report If the call recipient hangs up the telephone without any acknowledgement the Control Panel will red...

Page 29: ...pplication is available in both Android phone and iPhone version You can download the app for free by searching Connect2Home in Google Play or Apple App Store The application is only compatible with iPhone and Android phone it does not support iPad or Android tablet computer For iPhone user iOS 6 1 or higher version is required For Android user Android 2 2 or higher version is required How do I us...

Page 30: ...nsatisfactory consider changing Control Panel location or try different GSM service provider Enter Programming Mode and select Reset GSM to reset GSM module Interference Perform Walk Test on all your devices to check if Control Panel can still receive their signals Use Test Call function to test if Control Panel can report normally to programmed telephone number PIR Sensor PIR LED flashes when act...

Page 31: ...magnet and the Door Contact Reduce the gap and test the Door Contact again Remote Controller Remote Controller LED glows dimly when any key is pressed Remote Controller on low battery Factory Reset The Factory Reset function will delete all learned in devices and returns all system setting to default value After the setting you will need to setup the system again from the beginning via First Time ...

Page 32: ...lay 2x16 character LCD Keypad 17 keys keypad Siren Output 96 dBA sound pressure 1m minimum Zones 30 radio devices Plus 4 optional Power Switches Power Supply DC9V 1A Power Adaptor Battery 4 8V 600mAH Ni MH Rechargeable Battery charge time 72 hours Battery Backup Time 18 hours PIR Sensor Radio Frequency 433MHz Battery 2 x 1 5V AA alkaline batteries Door Contact Radio Frequency 433MHz Battery 2 x 1 ...

Page 33: ...2 05 FCC FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party re...

Reviews: