![Blaupunkt Q3000 Installation Manual Download Page 9](http://html1.mh-extra.com/html/blaupunkt/q3000/q3000_installation-manual_2771789009.webp)
6
Mounting
Door Contact
1.
Pull out the plastic battery insulator on the back to activate battery and
power on Door Contact.
2.
The Door Contact should be mounted on the door/window frame, while
the magnet should be mounted on the door/window aligned with the
Rib Mark on the Door Contact. The gap between the Door Contact and
the magnet should be no more than 15 mm.
3.
Choose to install the Door Contact with either screw or adhesive tape
Screw Mounting
The Door Contact has two knockouts on the inside of the back cover
where plastic is thinner for wall mounting.
4.
Open the Door Contact back cover to reveal the knockouts, break
through the knockouts and use the knockouts to mark position on door
or window frame
5.
Drill holes into door or window frame at marked location, insert plugs if
needed.
6.
Screw the back cover into marked location and replace the front cover.
7.
Screw the magnet onto the door, the position of the magnet should be
aligned with the rib mark on the Door Contact at the same height. If
the magnet cannot be placed at same height of Door Contact, a
spacer is provided in the package to increase the magnet height.
Adhesive Mounting
Before mounting with double side adehesive tape, you should clean the mounting location
with degreaser and make sure there is no cracked paint or uneven surface.
4.
Unpeel the cover on the double side adhisive tape, apply the tape to the back of Door Contact,
then apply the Door Contact to door or window frame
5.
Use another double side adhesive tape to install the magnet on the door/window.
PIR Sensor
The PIR Sensor has knockouts on the back where plastic is thinner.
The 2 central knockouts are for flat wall mounting, and the 4 side
knockouts are for corner mounting.
1.
Pull out the plastic battery insulator on the back to activate
batteries and power on PIR Sensor.
2.
Open the PIR Sensor back cover, break through the knockouts
and use the knockouts to mark position on wall or corner.
3.
Drill holes into the wall or corner at marked location, insert wall
plugs if needed.
4.
Screw the back cover into marked location and replace the front
cover.
Door/
Window
Frame
Knockouts
Tamper
Switch
Battery
Insulator
Surface Fixing
Knockouts x 2
Corner Fixing
Knockouts x 4