Blaupunkt Q3000 Installation Manual Download Page 9

 

 

 

 

Mounting 

Door Contact

 

1. 

Pull out the plastic battery insulator on the back to activate battery and 
power on Door Contact. 

2. 

The Door Contact should be mounted on the door/window frame, while 
the  magnet  should  be  mounted  on  the  door/window  aligned  with  the 
Rib Mark on the Door Contact. The gap between the Door Contact and 
the magnet should be no more than 15 mm. 

3. 

Choose to install the Door Contact with either screw or adhesive tape 

Screw Mounting 

The Door Contact has two knockouts on the inside of the back cover 
where plastic is thinner for wall mounting. 

4. 

Open  the  Door  Contact  back  cover  to  reveal  the  knockouts,  break 
through the knockouts and use the knockouts to mark position on door 
or window frame 

5. 

Drill holes into door or window frame at marked location, insert plugs if 
needed. 

6. 

Screw the back cover into marked location and replace the front cover. 

7. 

Screw the magnet onto the door, the position of the magnet should be 
aligned  with  the  rib  mark  on  the  Door  Contact  at  the  same  height.  If 
the  magnet  cannot  be  placed  at  same  height  of  Door  Contact,  a 
spacer is provided in the package to increase the magnet height. 

Adhesive Mounting 

Before  mounting  with  double  side  adehesive  tape,  you  should  clean  the  mounting  location 
with degreaser and make sure there is no cracked paint or uneven surface. 

4. 

Unpeel the cover on the double side adhisive tape, apply the tape to the back of Door Contact, 
then apply the Door Contact to door or window frame 

5. 

Use another double side adhesive tape to install the magnet on the door/window. 

PIR Sensor

 

The  PIR  Sensor  has knockouts  on the  back  where  plastic  is thinner. 
The  2  central  knockouts  are  for  flat  wall  mounting,  and  the  4  side 
knockouts are for corner mounting.  

1. 

Pull  out  the  plastic  battery  insulator  on  the  back  to  activate 
batteries and power on PIR Sensor. 

2. 

Open  the  PIR  Sensor  back  cover,  break  through  the  knockouts 
and use the knockouts to mark position on wall or corner. 

3. 

Drill  holes  into the  wall  or  corner  at marked  location,  insert  wall 
plugs if needed. 

4. 

Screw the back cover into marked location and replace the front 
cover. 

 

 

 

Door/ 
Window 

Frame 

Knockouts 

Tamper  
Switch 

Battery 
Insulator 

Surface Fixing 
Knockouts x 2 

Corner Fixing 
Knockouts x 4 

Battery 
Insulator 

Summary of Contents for Q3000

Page 1: ...Q3000 Smart Home Alarm Kit Content and Installation Guide...

Page 2: ...____________________4 3 Troubleshooting Factory Reset ________________________________________7 4 Specifications ________________________________________________________9 Information and illustrations...

Page 3: ......

Page 4: ...ich in turn sends notification to user via email or smartphone push notification The Control Panel is puposedly designed to resemble the appearnce of a speaker and blend in your home environment Statu...

Page 5: ...Rib mark when installed PIR Sensor The PIR Sensor raises alarm upon detecting intruder Parts Identification LED Indicator Learn Test Button The LED will light up if the PIR Camera detects movement und...

Page 6: ...er improve the capability of your alarm system by purchasing extra accessories Such as extra PIR Sensor or Door Contract to extend your protection area Remote Keypad for a secondary system operation p...

Page 7: ...ed alarm when triggered With Home Arm mode you can keep your home perimeter under alert and still be able to move freely within the house Home Arm mode allows system to be partially armed by deactivat...

Page 8: ...ocation that faces intruder directly Do not mount the PIR Sensor directly exposed to sunlight which may affect detection sensitivity Do not point PIR Sensor at window moving object or sources of heat...

Page 9: ...et cannot be placed at same height of Door Contact a spacer is provided in the package to increase the magnet height Adhesive Mounting Before mounting with double side adehesive tape you should clean...

Page 10: ...Sensor PIR Camera LED flashes when activated PIR is on low battery or tamper switch triggered PIR does not respond to movement PIR has a built in 1 minute sleep timer after detecting a movement PIR w...

Page 11: ...up the system by following the instruction in server user manual 1 Power down Control Panel by disconnecting AC Power and switching off battery switch 2 Apply AC Power while holding down the button on...

Page 12: ...ding construction device location and environment Control Panel Siren Output 96 dBA sound pressure 1m minimum Zones 40 radio devices Radio Frequency 868MHZ 2 4 GHz Power Supply DC9V 1A Power Adaptor B...

Page 13: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferenc...

Reviews: