FUNZIONAMENTO
I
53
OPERATION
GB
53
TLC
1: On/Off motor
2: - motor
3: On/Off
4: + motor
5: On/Off light
Note: the LED on the hood indicates the various speeds: green 1st speed, orange 2nd speed, red
3rd speed and flashing red 4th speed. „If the remote control unit is changed, the appliance must be
reset to the frequency of the new unit as follows:
Initialization procedure:
1. Cut off power to the hood
2. Power the hood again
3.Within the first 5 sec, press the light button and release it after the lights turn on (the control must be turned
on via key 3)
4. Within 5 sec, press the motor key and release it
Now you have to wait for about 10 seconds – then you can use the hood normally.
Notes: after 4 hours from the last use of a key, the hood turns off automatically.
Should there be interferences with other nearby remote controls, carry out the code change procedure.
Should it be required to replace the radio control, the frequency of the electronic system of the new radio
control must be calibrated again via the initialization procedure.
Procedure for generating a new code for the cooktop.
The radio control is supplied with default codes. If you want to generate new random codes, proceed as follows:
remove and restore power to the cooktop, within 5 seconds press simultaneously the two plus and minus keys
for at least 10 seconds; the LED will turn on, then press the two keys again (within 3 seconds). The LED flashes
three times to indicate that the operation has been completed. Once you changed the radio control you must
run again the initialization procedure.
1
2
3
4
5
Summary of Contents for 5IB64210
Page 2: ......
Page 35: ......
Page 36: ...Montage...
Page 38: ...5IE64251 EG1316 4 r7 4 Fl chenb ndige Kochfelder 5IB64210 EG 1377...
Page 39: ...5IE84251 EG1317 5II84250 EG1318 4 4 r7 Fl chenb ndige Kochfelder...
Page 40: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ...AFLIPC01BP Ed 07 02 17...