MODIFICATIONS AND OPTIONS
VENTO Ergo A25-1 Pro
Unit with a flat front panel for 300 up to 570 mm walls.
VENTO Ergo A25-1 S Pro
Unit with a flat front panel for 120 up to 500 mm walls.
ATTENTION
Unit – 1 item;
Fixing set – 1 item;
Operation manual – 1 item;
Remote controller – 1 item;
Packing box – 1 item.
Fig. 3. VENTO Ergo A25-1 Pro
Fig. 4. VENTO Ergo A25-1 S Pro
•
Polluted warm air is extracted from the room and while flowing
through the heat exchanger warms it up and transfers a part of
humidity.
•
After the ceramic heat exchanger gets warmed up the unit changes
into air supply mode.
•
While flowing through the heat exchanger fresh cold air
from outside absorbs accumulated heat and moisture.
•
As the heat exchanger cools down the unit changed into
air extract mode.
Unit operation logic in winter time
Cycle 2
(70 seconds)
Air extraction from the room
Cycle 1
(70 seconds )
Air extraction from the room
OUTSIDE
OUTSIDE
INSIDE
+17 °C
+20 °C
-7 °C
-10 °C
The unit has four ventilation modes:
•
Ventilation
- the unit operates in permanent extract or supply
mode, depending of the CN7 jumper position. The jumper is set to
extract (out) mode by default.
•
Air Supply
- the unit operates in supply mode no matter CN7
jumper position.
•
Passive Air Supply
– the fan is off, the automatic shutters are
opened and the room is ventilated in the natural way.
•
Heat Recovery
– the unit operates in reversible mode with heat and
humidity recovery.
In
Heat Recovery mode
the air supply and air extract modes are changed
every 70 seconds.
Fig. 2. Operation logic