MANUFACTURER'S WARRANTY 

The fan complies with the requirements according to the EU norms and 
directives, to the relevant EU-Low Voltage Equipment Directives, 
EU-Directives on Electromagnetic Compatibility. 
We hereby declare that the following product complies with the essential 
protection requirements of Electromagnetic Council Directive 2004/108/EC, 
89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and 
CE-marking Directive 93/68/EEC on the approximation of the laws of the 
Member States relating to electromagnetic compatibility. 
This certificate is issued following test carried out on samples of the product 
referred to above. Assessment of compliance of the product with the 
requirements relating to electromagnetic compatibility was based on the 
following standards.
Protection degree index according to IP rating against access to hazardous 
parts and water ingress is  IP 45 for Sileo 100, Sileo 125, Sileo 150 and 
IP X5 for Sileo Max 150 model. The fan is double insulated and does not 
require grounding. 
The warranty operation period (service life) of the fan is five years from the 
retail sale date provided observance of the installation and operation 
regulations.
In case of the product malfunctions caused by a manufacturing fault 
during the warranty period the consumer is entitled for the fan replacement 
or its warranty repair. 

WARNING!!! 
In case of a claim for the product replacement  please submit the operation 
manual with the sales confirmation and/or a payment document that 
confirms the product sales. If case of no confirmation of the sale date, 
the warranty term shall be calculated from the manufacturing date.

By purchasing this product the user confirms to have read and 
accepted the operation manual conditions as well as operation, 
storage, transportation, mounting, setup, wiring, servicing, repair 
and warranty rules applicable to the product stated in the attached 
technical documentation. 

Do not dispose in domestic waste. The product contains in part material 
that can be recycled and in part substances that should not end up as 
domestic waste. Dispose of the product once it has reached the end 
of its working life according to the regulations valid where you are.

Summary of Contents for Sileo

Page 1: ...EN Sileo Service Instructions ...

Page 2: ...chnical description technical data sheets operation and mounting guidelines safety precautions and warnings for safe and correct operation of the fan BLAUBERG Sileo USE BLAUBERG Sileo fan is designed for ventilation of residential and public premises heated during winter season and is constructed for wall or ceiling mounting fig 2 4 The fan is equipped with a back valve to prevent air backdrafting...

Page 3: ...leo 125 SH Sileo 125 IR Sileo 150 Sileo 150 S Sileo 150 T Sileo 150 H Sileo 150 ST Sileo 150 SH Sileo 150 IR Sileo Max 150 Sileo Max 150 S Sileo Max 150 T Sileo Max 150 H Sileo Max 150 ST Sileo Max150 SH Sileo Max 150 IR Switch integrated pull cord switch Timer turn on delay timer adjustable from 0 up to 2 minutes only Sileo 150 and Sileo Max 150 models and turn off delay timer adjustable from 2 u...

Page 4: ... for continuous operation always connected to power mains The air motion direction in the system must match the pointer on the fan casing The fan is rated for operation at ambient temperature from 1 C up to 45 C The fan does not require grounding 24 Fig 1 Sileo 125 Sileo 150 Sileo Max 150 a 158 182 214 b 136 158 190 c 81 91 98 d 99 124 148 e 26 27 32 ...

Page 5: ...bjects which can damage the impeller blades Misuse of the fan or any unauthorized modification are not allowed Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to...

Page 6: ... ceiling or wall mounting and installation into a ventilation shaft or connection to a round air duct of respective diameter fig 2 4 The fan mounting sequence is shown in fig 5 13 The wiring diagrams are shown in fig 14 25 26 Fig 2 Fig 4 Fig 3 ...

Page 7: ...27 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 ...

Page 8: ...28 Fig 10 Fig 11 Fig 12 Fig 13 ...

Page 9: ...25 ST SILEO 100 125 SH SILEO 100 125 IR SILEO 100 125 T SILEO 100 125 H QF S QF S QF QF S QF S SILEO 100 125 1 2 3 N L QF S 1 2 3 N L QF S SILEO 150 SILEO MAX 150 N L N L N L N L N L N L N L N L N L N L LT LT Fig 15 Fig 14 Fig 16 Fig 17 first speed ...

Page 10: ... 150 1 2 3 S N L QF S speed 1 2 3 S N L QF S speed 1 2 3 N L QF CDP 2 5 1 2 3 N L QF CDP 2 5 SILEO 150 S SILEO MAX 150 S 1 2 3 N L QF 1 2 3 N L QF SILEO 150 S SILEO MAX 150 S Fig 20 first speed Fig 18 second speed Fig 19 first and second speed Fig 21 second speed ...

Page 11: ...0 T SILEO 150 H SILEO MAX 150 H 1 2 3 N L QF S 1 2 3 N L QF S SILEO 150 ST SILEO MAX 150 ST SILEO 150 SH SILEO MAX 150 SH SILEO 150 IR SILEO MAX 150 IR 2 3 N L QF 1 2 3 N L QF SILEO 150 SILEO MAX 150 SILEO 150 S SILEO MAX 150 S Fig 22 first and second speed Fig 23 Fig 24 Fig 25 ...

Page 12: ...ustments You can use the screwdriver to change the turn on only Sileo150 and Sileo Max 150 models and turn off delay timer settings and to set the DIP switch into a required position only Sileo150 and Sileo Max 150 models Do not use a metal screwdriver knife etc for adjustment operations not to damage the circuit board Sileo 100 125 Sileo 150 Sileo Max 150 2 min 0 min Ton 2 min 30 min Toff 2 min 3...

Page 13: ... The fan starts running at the first speed in case of actuation of any sensor or the switch closing Mode 2 two speed mode The fan is turned off by default The fan starts running at the second speed in case of actuation of any sensor or the switch closing Mode 3 two speed mode The fan runs at the first speed by default The fan starts running at the second speed in case of actuation of any sensor or...

Page 14: ...2 3 4 Operation mode 1 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 Sileo 150 H Sileo Max 150 H Sileo 150 SH Sileo Max 150 SH FAN OPERATION MODE INDICATION The light indicator glows yellow during operation of all the Sileo 100 Sileo 125 models as well as Sileo 150 Sileo Max 150 basic and S models The light indicators glows as shown in fig 27 during operation of the fan models Sileo 150 and Sileo Ma...

Page 15: ... rises above the set point from 60 up to 90 the fan either turns on or switches to the second speed depending on the set operation mode with respect to the turn on delay timer setting The fan keeps operating at this speed until the humidity drops to the set point After that the turn off delay timer is activated Motion sensor in case of motion detection the fan either turns on or switches to the se...

Page 16: ...enance operations Maintenance means regular cleaning of the fan surfaces of dirt and dust To clean the fan wipe its surfaces with a cloth wetted in a mild soap solution then wipe the surfaces dry fig 28 33 Avoid water dripping on the motor and circuit board 36 Fig 28 Fig 29 Fig 30 ...

Page 17: ...he manufacturer s original package Store the delivered product in the manufacturer s original packing box in a dry ventilated premise with the ambient temperature from 5 C up to 40 C and relative humidity less than 80 The storage environment must be free of dust acid or alkali vapours to prevent corrosion Fig 31 Fig 32 Fig 33 ...

Page 18: ...es not require grounding The warranty operation period service life of the fan is five years from the retail sale date provided observance of the installation and operation regulations In case of the product malfunctions caused by a manufacturing fault during the warranty period the consumer is entitled for the fan replacement or its warranty repair WARNING In case of a claim for the product repla...

Page 19: ...39 ACCEPTANCE CERTIFICATE ...

Page 20: ...SALES DATE MANUFACTURED ON DATE Fan is recognized as serviceable SILEO_DE_EN 05 SOLD APPROVAL MARK S T H ST SH IR 100 125 150 Sileo Max Sileo ...

Reviews: