www.blaubergventilatoren.de
7
FRESHBOX E120
General mounting sequence is shown in Fig. 5.
Unit mounting using
MS2 FRESHBOX E120
:
Fix the master plate on the wall at a required height using a sealing
tape. Use the master plate to mark two Ø 130 mm holes for the air ducts and
four Ø 8 mm holes for the fasteners.
Remove the master plate and drill through holes for the air ducts and
90 mm deep holes for the fasteners. Install the dowels, remove the perforated
master plate parts and fi x the master plates on both sides of the wall using a
sealing tape.
Fix the outer ventilation hood AH FRESHBOX E120 on outer side.
Insert the air ducts into the mating master plate holes and connect
those to the outer hood connection piece.
Fix the gaps between the air ducts and the wall with a mounting foam
through openings in the master plate. After the mounting foam hardening
remove the master plate, the foam excess and cut the protruding parts of the
air ducts to be fl ush with the wall.
Open the unit panel and remove the heat exchanger.
Insert the unit spigots into the air ducts.
Fix the unit on the wall with countersunk screws and 8x80 dowels
included in the delivery set by installing those in four Ø 8 mm holes.
Install the heat exchanger and close the unit panel.
UNIT
TWO AIR DUCT Ø 125 MM
FOUR DOWELS
AND SCREWS
FOUR DOWELS AND SCREWS
(INCLUDED IN THE OUTER HOOD
DELIVERY SET)
OUTER HOOD
Fig. 5. Unit mounting