background image

www.blaubergventilatoren.de

Solo a35/50/60 S4 Pro r (v.2)

12

+

CR2025

   3V

+

CR2025

   3V

3. Replacing the battery in the remote control (when needed).
No response of the ventilator for pressing the remote control buttons 
indicates the need to replace the battery.
The battery type is CR2025.
To replace the battery of the remote control, remove the battery 
holder with a battery.
Replace the battery and install the holder with a new battery back 
to the remote control.

POSSIBLE FAULTS AND TROUBLESHOOTING

Problem

Possible reasons

Troubleshooting

When switching on the 

ventilator the fan does not 

start.

No power supply.

Make sure the power supply line is connected 

correctly, otherwise troubleshoot the connection 

error.

The motor is jammed, the impeller blades are soiled.

Turn the ventilator off. Troubleshoot the motor jam 

and the impeller clogging. Clean the blades. Turn the 

ventilator on.

Circuit breaker tripping 

during the ventilator start-up.

Overcurrent as a result of short circuit in the electric 

circuit.

Turn the ventilator off. 

Contact the Seller for further information.

Low air flow.

Low set fan speed.

Set higher speed.

The filters, the fan or the regenerator are clogged.

Clean or replace the filter. Clean the fan and the 

regenerator.

Noise, vibration.

The impeller is clogged.

Clean the impeller.

Loose screw connection of the ventilator casing or the 

outer ventilation hood.

Tighten the screws of the ventilator or the outer 

ventilation hood.

Summary of Contents for Solo A35 S4 Pro R

Page 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Solo A35 S4 Pro R Solo A35 S4 Pro R V 2 Solo A50 S4 Pro R V 2 Solo A60 S4 Pro R V 2...

Page 2: ...ence and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not p...

Page 3: ...tion The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in motor...

Page 4: ...rated for continuous operation NAME NUMBER Solo A35 S4 Pro R Solo A35 S4 Pro RV 2 Solo A50 S4 Pro RV 2 Solo A60 S4 Pro RV 2 Ventilator 1 pc 1 pc Remote control 1 pc Plastic screwdriver 1 pc Mounting p...

Page 5: ...nst access to hazardous parts and water ingress is IP24 The unit design is constantly being improved thus some models may be different from those described in this manual The technical data of the spe...

Page 6: ...hrough the regenerator which gradually absorbs heat and humidity In 60 seconds as the regenerator gets warmed up the ventilator is switched to the supply mode CYCLEII Fresh intake air from outside flo...

Page 7: ...diameter depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the Technical data section D1 min 300 min 300 min 300 A A A A 2 Install the air duct int...

Page 8: ...screw the self tapping screw from the casing and remove the front part of the indoor unit 5 Attach the mounting plate and mark holes for the dowels with a pencil or marker Drill the holes and insert t...

Page 9: ...mains using a cord with a plug with a switch on the wire Switching from the first speed to the second is carried out only by a standard pull cord switch Speed switch speed I II ON OFF 230 V 50 Hz CONN...

Page 10: ...button on the remote control the ventilator starts to operate at the speed at which it was switched off When switched on using buttons I or II the ventilator starts to operate at the corresponding sp...

Page 11: ...the self tapping screw Remove the four screws retaining the indoor unit then pull it out of the air duct Consequently remove all elements of the ventilator 1 Clean the filters as they get clogged but...

Page 12: ...the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed the impeller blades are soiled Turn the ventilator off Troubleshoot the motor jam and the i...

Page 13: ...suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried...

Page 14: ...Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s man...

Page 15: ...TION CERTIFICATE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Insta...

Page 16: ...www blaubergventilatoren de B132EN 09...

Reviews: