WARNING

!

Disconnect the fan from power supply prior to any connection, servicing 
and repair operations.
  

Only duly qualified electricians with valid electrical permit for electric 
operations at the units with operating voltage up to 1000 V are allowed 
for mounting and maintenance after careful study of the present 
user's manual.  

The single-phase power mains must comply with the acting local electrical 
norms and standards.  
The fixed electrical wiring must be equipped with an automatic circuit 
breaker. 

The fan must be connected to power mains through an automatic circuit 
breaker QF integrated into the fixed wiring system with the gap between 
the breaker contacts on all poles not less than 3 mm.  

Check the fan for any visible damages of the impeller and the casing before 
starting installation. The casing internals must be free of any foreign objects 
which can damage the impeller blades.   

Due to constant improvements the design of some models may slightly 
differ from those ones described herein. 

Follow the user's manual requirements to ensure durable 
and trouble-free operation of the fan. 

While mounting the fan do not compress the casing!  

Deformation of the casing may result in the motor jam and noisy operation.  

Misuse of the fan and any unauthorised modifications are not allowed. 

Take steps to prevent ingress of smoke, carbon monoxide and other 
combustion products into the room through open chimney flues or other 
fire-protection devices. Sufficient air supply must be provided for proper 
combustion and exhaust of gases through the chimney of fuel burning 
equipment to prevent back drafting.  

Transported air must not contain any dust or other solid impurities, sticky 
substances or fibrous materials.  

3

WARNING

!

Follow the user's manual requirements to ensure durable 
and trouble-free operation of the fan. 

Summary of Contents for Ducto

Page 1: ...Ducto Operation manual AXIAL FANS EN...

Page 2: ...ring must be equipped with an automatic circuit breaker The fan must be connected to power mains through an automatic circuit breaker QF integrated into the fixed wiring system with the gap between th...

Page 3: ...combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of f...

Page 4: ...n the fan and do not put objects on it The timer circuit is live Disconnect the fan from power supply prior to any adjustment operations The fan delivery set includes a specially designed plastic scre...

Page 5: ...that they have been given supervision or instruction regarding a safe use of the product and understand the risks involved Do not allow children play with the product 5 The product must be collected s...

Page 6: ...er on the fan casing The fan is rated for operation at the ambient air temperature from 1 C up to 45 C Ingress protection rating against access to hazardous parts and water ingress is IPX4 The fan req...

Page 7: ...ts operating at the low speed as the external switch supplies power voltage to the LT input terminal for instance during switching the light on After the control signal is off the fan continues operat...

Page 8: ...e the switching time respectively adjustable from 1 up to 15 hours To adjust the operation time at the high speed and turn off delay time for activation of the low speed after turning the switch off r...

Page 9: ...9 EN 3 1 4 2...

Page 10: ...10 EN QF L N 5 6 7 8 9 10...

Page 11: ...iring diagrams 2 1 S QF L N QF N N L L LT S Ducto 100 125 150 Ducto 100 125 150 T Ducto Power Plus 100 125 150 1 2 3 S N L QF 2 high speed 3 low speed S speed Ducto Plus Ducto Power Plus 100 125 150 T...

Page 12: ...12 18 17 Ducto 100 125 150 T Ducto Plus Ducto Power Plus 100 125 150 T 2 min 30 min Toff 2 min 30 min Toff HS time 0 min 2 min Ton OR 1 hour 15 hour Tint...

Page 13: ...rements of Electromagnetic Council Directive 2004 108 EC 89 336 EEC and Low Voltage Directive 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member Sta...

Page 14: ...14 ACCEPTANCE CERTIFICATE...

Page 15: ...15 Ducto 100 125 150 Ducto Ducto U T Plus Power Plus Approval mark Manufacturing date Sales date Sold name and stamp of the seller Acceptance certificate The fan is recognized as serviceable...

Page 16: ...B01 Ducto EN 02...

Reviews: