www.ventilation-system.com
Box/Box-I/Box-f/Box-fI
8
Box-F/Box-FI
40x20 4E
40x20 4D
50x25 4E
50x25 4D
50x25 6E
Unit voltage [V/50 (60) Hz]
1~ 230
3~ 400
1~ 230
3~ 400
1~ 230
Power [W]
295
282
535
570
244
Current [A]
1.32
0.60
2.49
0.94
1.22
Maximum air flow [m
3
/h]
1440
1470
1750
1850
1460
RPM [min
-1
]
1350
1300
1250
1270
910
Sound pressure level at 3 m distance [dBA]
50/42*
52/43*
53/44*
54/44*
45/37*
Transported air temperature [°С]
-25...+40
-25...+45
-20...+40
-20...+40
-20...+50
Ingress protection rating of the unit
IPX4
IPX4
IPX4
IPX4
IPX4
Electric motor IP rating
IP54
IP54
IP54
IP54
IP54
Box-F/Box-FI
50x25 6D
50x30 4E
50x30 4D
50x30 6E
50x30 6D
Unit voltage [V/50 (60) Hz]
3~ 400
1~ 230
3~ 400
1~ 230
3~ 400
Power [W]
274
710
855
283
303
Current [A]
0.67
3.10
1.70
1.59
0.8
Maximum air flow [m
3
/h]
1490
2350
2350
1550
1620
RPM [min
-1
]
930
1230
1300
890
910
Sound pressure level at 3 m distance [dBA]
45/38*
57/47*
56/47*
47/39*
51/41*
Transported air temperature [°С]
-20...+60
-25...+70
-20...+50
-20...+70
-20...+60
Ingress protection rating of the unit
IPX4
IPX4
IPX4
IPX4
IPX4
Electric motor IP rating
IP54
IP54
IP54
IP54
IP54
Box-F/Box-FI
60x30 4E
60x30 4D
60x30 6E
60x30 6D
60x35 4E
Unit voltage [V/50 (60) Hz]
1~ 230
3~ 400
1~ 230
3~ 400
1~ 230
Power [W]
1240
1560
419
397
2840
Current [A]
6.45
2.73
2.05
0.78
13.90
Maximum air flow [m
3
/h]
2950
3740
2260
2320
4260
RPM [min
-1
]
1210
1310
870
920
1260
Sound pressure level at 3 m distance [dBA]
59/51*
57/50*
50/42*
49/41*
59/51*
Transported air temperature [°С]
-25...+50
-25...+65
-20...+70
-20...+70
-20...+40
Ingress protection rating of the unit
IPX4
IPX4
IPX4
IPX4
IPX4
Electric motor IP rating
IP54
IP54
IP54
IP54
IP54
* Parameters for a Box-FI model.