BLAUBERG Ventilatoren Axis-F 200 2E User Manual Download Page 3

www.blaubergventilatoren.de

axis-Q / axis-Qr / axis-f / axis-Qa / axis-Qra / tubo-f / tubo-M(Z) / tubo-Ma(Z)

3

•  Do not change the power cable length at 

your own discretion. 

•  Do not bend the power cable. 
•  Avoid damaging the power cable. 
•  Do not put any foreign objects on the 

power cable.

•  Do not lay the power cable of the unit in 

close proximity to heating equipment.

•  Do not use damaged equipment or cables 

when connecting the unit to power mains.

•  Do not operate the unit outside the 

temperature range stated in the user’s 
manual. 

•  Do not operate the unit in aggressive or 

explosive environments.

•  Do not touch the unit controls with wet 

hands. 

•  Do not carry out the installation and 

maintenance operations with wet hands.

•  Do not wash the unit with water. 
•  Protect the electric parts of the unit against 

ingress of water. 

•  Do not allow children to operate the unit.

•  Disconnect the unit from power mains prior 

to any technical  maintenance.

•  Do not store any explosive or highly 

flammable substances in close proximity to 
the unit.

•  When the unit generates unusual sounds, 

odour, or emits smoke, disconnect it from 
power supply and contact the Seller.

•  Do not open the unit during operation.

•  Do not direct the air flow produced by the 

unit towards open flame or ignition sources.

•  Do not block the air duct when the unit is 

switched on.

•  In case of continuous operation of the unit, 

periodically check the security of mounting.

•  Do not sit on the unit and avoid placing 

foreign objects on it.

•  Use the unit only for its intended purpose.

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC  WASTE.

Summary of Contents for Axis-F 200 2E

Page 1: ...Industrial electric axial fans EN USER S MANUAL Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z...

Page 2: ...rating staff The manual contains information about purpose technical details operating principle design and installation of the Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z unit an...

Page 3: ...h the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance...

Page 4: ...D BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTE...

Page 5: ...0 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Power W 250 325 151 161 420 455 220 268 550 654 330 375 750 979 540 610 Current A 1 2 1 46 0 78 0 8 1 95 2 05 1 1 1 22 2 55 2 88 1 6 1 63 3 5 4 26 2 4 2 74...

Page 6: ...50 30 60 30 50 30 60 30 50 30 60 30 60 30 60 30 60 IP rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 Motor IP rating IP24 IP24 IP24 IP24 IP24 IP24 IP44 IP44 IP44 IP44 Parameters Axis QA Axi...

Page 7: ...350 4E Axis QR 350 4D 374 442 460 9 165 7 5 Axis QR 400 4E Axis QR 400 4D 417 504 528 9 220 8 5 Axis QR 450 4E Axis QR 450 4D Axis QR 450 6E Axis QR 450 6D 465 578 607 11 230 10 0 Axis QR 500 4E Axis...

Page 8: ...1 Axis QA Model Dimensions mm Weight kg D D1 D2 d L Axis QRA 150 162 190 220 7 120 2 5 Axis QRA 200 208 270 300 7 120 2 5 Axis QRA 250 262 330 360 7 140 3 0 Axis QRA 315 312 390 420 9 170 5 1 Axis QRA...

Page 9: ...equipped with RSM Z polymer coated steel galvanized steel reducers for connection to 150 mm 200 mm and 250 mm air ducts The reducers are not included in the delivery set and must be ordered separatel...

Page 10: ...otective ground circuit Axis Q Axis QR 3 4 1 2 5 3 4 1 2 TheAxis QAandAxis QRAfansconsistofacasing1madeofpolymer coatedstainlesssteelwithasquare Axis QA orround Axis QRA flange to which the grille 2 i...

Page 11: ...and deformations Set the impeller in motion and check that it rotates freely without catching against the inlet flange and the casing Prior to powering up the fan make sure that the mains parameters...

Page 12: ...www blaubergventilatoren de Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z 12 Axis Q fan installation Axis QR fan installation...

Page 13: ...www blaubergventilatoren de Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z 13 Axis QA and Axis QRA fan installation...

Page 14: ...y so that the direction of the arrow shown on the casing matches the direction of air flow in the system The power is supplied via the remote position terminal box Tubo F andTubo MA Z fan installation...

Page 15: ...er ducts Once done the assembly is secured with clamps The power is supplied via terminal box on the fan casing The Tubo M Z delivery set includes mounting brackets for attaching the unit to the mount...

Page 16: ...ata table The recommended trip current of the circuit breaker is the next current in the standard trip current row following the maximum current of the connected unit The automatic circuit breaker is...

Page 17: ...www blaubergventilatoren de Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z 17 Axis Q and Axis QR fan connection Axis QA fan connection...

Page 18: ...www blaubergventilatoren de Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z 18 Axis F Tubo M Z Tubo MA Z fan connection Tubo F fan connection...

Page 19: ...t solution while avoiding water penetration onto the electric motor Wipe the cleaned surfaces dry To carry out technical maintenance of the Axis F Tubo M Z Tubo MA Z Tubo F fans remove the fans from t...

Page 20: ...www blaubergventilatoren de Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Z Tubo MA Z 20 Axis QA and Axis QRA technical maintenance Tubo F Tubo M Z Tubo MA Z technical maintenance...

Page 21: ...hat the air dampers and louvers are open If the malfunction is too complex to be eliminated on the spot contact the fan Seller STORAGE AND TRANSPORTATION REGULATIONS Store the unit in the manufacturer...

Page 22: ...the user s manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated...

Page 23: ...TALLATION CERTIFICATE The Axis Q Axis QR Axis F Axis QA Axis QRA Tubo F Tubo M Tubo MA _____ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Compa...

Page 24: ...www blaubergventilatoren de B03EN 11...

Reviews: