h)

 

If the length of the brushes is, due to wear, less than 5mm or they are extremely deformed, the brushes 

have to be replaced. Check the Service Manual for the order numbers. 

i)

 

All repair work has to be done by qualified Blastrac personnel, this guarantees a safe and reliable 

machine.

  

j)

 

Always use original Blastrac spare parts, grinding disks and polishing pads. This will ensure the 

best performance. 

Only original parts meet the factory specifications and quality.  Otherwise Blastrac BV cannot guarantee 

the safety of the machine. 

The part numbers can be found in the Service Manual.  

k)

 

Check the rotating direction of the motor before operation. The correct direction is given with an arrow on 

the housing of the motor.  

l)

 

If safety-critical changes occur to the machine or its working method, the machine must be shut down 

immediately! The cause of the fault must be established, and rectified. 

m)

 

In the event of operational malfunctions the machine must be shut down immediately and secured! 

n)

 

Never use the machine without a suitable (Blastrac) dust collector! 

 

 

3.5 

Grinding safety 

a)

 

The machine contains rotating parts, which are protected with a cover. Always leave the diamond disc on 

the floor while the motor is turning. 

b)

 

The flexible coupling can become worn out with use, because of this there can be higher vibrations than 

normal. Check for this reason the flexible coupling for deformation and damage before every use. 

c)

 

Do not let the machine rest on the diamond disc or coupling when it is not in use, this will cause 

deformation to the flexible coupling.  

d)

 

Always put the machine on the machine support/transport wheel which is made especially for this reason. 

e)

 

Make sure the brush seals are in good condition, this to avoid dust escaping. 

f)

 

Make sure the diamond disc is not damaged or worn out. 

g)

 

Always pull out the main plug before u start changing the grinding disks or polishing pads. 

h)

 

When mounting or removing a diamond disc; lay down the machine so it is lying on the handle. Make sure 

the machine will not fall back down. A second person can hold the handle down, to make sure it will not 

fall back down. 

i)

 

When changing the disks u should wear Personal Protective Equipment like a dust mask, safety goggles, 

gloves, protective shoes, and close fitting protective clothing.  

Use the vacuum cleaner while changing the discs to prevent excessive dust.  

 

j)

 

Caution! The grinding disc will heat up during grinding, don’t risk getting burned, always wear 

protective gloves when handling them! 

k)

 

The machine contains rotating parts; because of this never pull the machine backwards with a turning 

motor.  

l)

 

Be careful with the machine and pull or let down the machine slowly, big shocks can damage the electrical 

parts. 

 

 

3.6 

Dustcollector safety 

a)

 

Always use a Blastrac dust collector to ensure a dust-free operation of the machine and clean air at the 

workspace. Also the airflow helps to cool the machine and prevents overheating. 

b)

 

When working on or around carcinogenic or pathogenic substances, the dust collector must be fitted 

with a HEPA filter. 

c)

 

Read the operating instructions of the dust collector before using it. 

d)

 

The dust container/bag of the dust collector must be emptied regularly. Comply with the local waste 

treatment regulations considering the removed material. 

e)

 

The dust hose must be connected properly with a hose clamp and industrial tape. 

f)

 

The dust hose must be undamaged and free of obstructions. 

g)

 

Always switch on the dust collector first! 

 

 

 

Summary of Contents for BG-250RS

Page 1: ...Original instructions in English OPERATING INSTRUCTIONS BG 250RS VERSION 1 1...

Page 2: ...s Repairs Cleaning Test on By Inspection before initial operation on __________________________________________ By __________________________________________ Date of initial operation ________________...

Page 3: ...Signs on the machine 10 4 Initial operation 11 4 1 Checkpoints of electrical safety 11 4 2 Checkpoints of machine safety 11 4 3 Checkpoints of work area 11 4 4 Manual moving of the machine 12 4 5 Cha...

Page 4: ...e machine Always use common sense when working with machines 2 Machine description The Blastrac grinding machine BG 250RS is an electrical driven remote controlled floor grinding machine for treating...

Page 5: ...ews etc Any stones screws bolts pieces of wire etc could cause serious damage to the machine if it gets inside the machine e Make sure there is enough ambient light on the work area Cluttered or dark...

Page 6: ...ut by the wire but by the connector n Be careful with water on the treated surface Electrical cables must not come into contact with water o The main power switch on the machine must be in the Off pos...

Page 7: ...is made especially for this reason e Make sure the brush seals are in good condition this to avoid dust escaping f Make sure the diamond disc is not damaged or worn out g Always pull out the main plug...

Page 8: ...als containing asbestos a recirculation of purified air in the work area are not allowed The following activities with the industrial vacuum cleaner or dust collector recirculation of purified air are...

Page 9: ...ound always use the lowest lifting speed The cables must first be tensioned at this speed they must not be slack when the machine is lifted from the ground f During hoisting make sure to be at a safe...

Page 10: ...CE mark on this machine Wear protecting gloves Safety shoes obliged Consult the manual before operating the machine Name address and CE mark The machine type The net weight of the machine in kilogram...

Page 11: ...regulations and directives in force this applies to the protective earth conductor in particular in order to ensure that all safety devices are functioning and to eliminate possible damage to electri...

Page 12: ...the right side of the bracket The traction wheels must be disconnected from the drive motors pull out the locking pin of each rear wheel The machine can now be pushed around on its wheels WARNING Alwa...

Page 13: ...ot fall back down A second person can hold the handle down to make sure it will not fall back down Loosen the 4 bolts with an appropriate key Remove the diamond or multiflail disc Mounting the diamond...

Page 14: ...Make sure nobody including yourself is in the surrounding area of at least 5 meter from the machine Push the RESET button 2 for 10 seconds To start grinding push the START button 5 Check the turning...

Page 15: ...depends on the material of the surface to be treated and the desired profiling Regularly check the contents of the dust collector Always wear a dust mask of at least class FFP3 when emptying the dust...

Page 16: ...cleaning agents Make sure the inside of the electrobox is dust free Every 3 months Clean the machine with a dust collector and a damp lint free cloth Annually Full overhaul and cleaning of the complet...

Page 17: ...ied Blastrac personnel Changes add on s or conversions are undertaken without written permission of Blastrac BV Screws bolts etc that have been removed must be replaced with those of the same quality...

Page 18: ...ry day with air and non aggressive materials Never use a high pressure water cleaner to clean the machine Remove the diamond disc after using the machine 6 2 Other maintenance Dust in the electrical b...

Page 19: ...age or fault contact an authorised service technician After every workday use air to blow the dust off the transmitter Weekly maintenance Clean the battery contacts and the contacts on the transmitter...

Page 20: ...grinding tool for the application Replace the worn parts Replace the grinding tools with appropriate grinding tools for the surface to be treated Motor does not switch on Missing phase Wrong power sup...

Page 21: ...ust hose connection 75 mm Suitable filter unit Contact Blastrac BV We will assist you with a good advice Design and specifications are subject to change without notice by Blastrac BV Vibration level D...

Page 22: ...achine is switched off or even running but not actually in use This may significantly decrease the exposure level over the total working period Ear protection is recommended with the use of this equip...

Page 23: ...info blastrac de WWW BLASTRAC DE BLASTRAC UKRAINE SALES SERVICE CENTRE Nezalezhnosti 14 of 21 07400 Brovary Tel 38 0 44 222 51 28 Fax 38 0 44 277 98 29 Email info blastrac com ua WWW BLASTRAC COM UA B...

Reviews: