![Blastrac 1-8DECMKI Operating Manual Download Page 42](http://html1.mh-extra.com/html/blastrac/1-8decmki/1-8decmki_operating-manual_2769634042.webp)
Operating Instructions 1-8DEC 230V
Troubleshooting
10.1 Troubleshooting
– Blast Unit
NOTE: ALL SERVICE OF BLASTRAC EQUIPMENT REQUIRES A
THOROUGH AWARENESS OF THE WARNINGS AND PRECAUTIONS IN
SECTION 1 OF THIS MANUAL
Troubleshooting List...Blast Unit...Mechanical Malfunctions
Trouble
Probable Cause
Remedy
Excessive vibration -
usually indicates that the
blast wheel is out of
balance. This condition
will eventually cause
bearing failure in the
motor or bearing unit.
Unevenly worn wheel.
Chipped, broken blades.
Replace wheel kit. Check
separator and ventilation system.
Chipped or broken blades will
permanently unbalance the blast
wheel and can cause damage to
other components. Change wheel
kit immediately.
Excessive noise - usually
indicates misaligned
components which
causes premature wear
and component failure.
Improper clearances or
alignments between
rotating parts, usually the
control cage and the
blast wheel.
Loose bolts or
mis-alignment.
Check alignment of control cage
and wheel. Allow sufficient
clearance between rotating parts.
Check bearing unit, belts, sheaves,
motor mounting, wheel housing
and any other associated parts to
be sure of alignment and that they
are firmly secured.
41
Summary of Contents for 1-8DECMKI
Page 18: ...17...
Page 19: ...18...
Page 20: ...19...
Page 29: ...Operating Instructions 1 8DEC 230V Edging Mode Section 6 6 1 Edging Mode 28...
Page 31: ...30...
Page 35: ...Operating Instructions 1 8DEC 230V Wear Parts Section 8 8 1 Wear Parts 8 2 Maintenance Log 34...
Page 50: ...Operating Instructions 1 8DEC 230V Specifications Section 12 12 1 Specifications 49...