![Blankom A-QAMOS-IPM User Manual Download Page 27](http://html1.mh-extra.com/html/blankom/a-qamos-ipm/a-qamos-ipm_user-manual_2769584027.webp)
27
of the headend. Here the NIT transmission per channel can
be switched on or off easily and the network name and
network ID can be changed. The settings are identical to the
menu
Settings
→
Transport stream processing
(
»chapter
7.2.5
).
Confirm and store with the “
Send
“ button.
7.2.12.2 Manual NIT processing
After the preparation or initializing of the NIT, described in
7.2.11, first it must be called the edit mode of the NIT in
each device of the A-QAMOS and QAMOS product group
of the headend, read the NIT of the device and stored on
the PC by clicking the
“
Export
“
button. Then you append
the NIT of the other mentioned devices, which belong to
the headend, by repeatedly pressing the
“
Import
“
button
in edit mode.
As opposed to the automatic NIT processing here appear
the added tables in white color. After the appropriate
selection of channels of the NIT and any change in the
network name or network ID the NIT of this device is stored
and transferred by pressing the
“
Send
“
button.
To facilitate the setting of all other mentioned devices in
the headend, this headend NIT can be stored in the PC by
clicking the
“
Export
“
button. Now all the other devices of
the A-QAMOS and QAMOS product group of the headend
have called successively, these stored NIT loaded by
pressing the
“
Import
“
button and then adopted and saved
by pressing the
“
Send
“
button.
For changes of the NIT is to be noted that these changes
must be made in the NIT of each device. It is therefore
recommended to prefer the automatic NIT processing of
the manual NIT processing.