Blankom 9650.03 Manual Download Page 18

GmbH

a

b

ANTENNENTECHNIK

Further information for timer configuration

RF - Signal:

This parameter is only available at the 1. selection box.
Not all modules support this configuration.
This can be done only if the respective module supprt switching/selection
of the RF-signal (see page 18)

Übernahme:

This function is only available at the 8. selection box
The adjustments of the input parameters will be overtaken without a reset

(see tabel page 20).

1. selection box

8. selection box

Example for an Einstellbox (Address,
Switchtime, Parameter, Werte)

Parameter-List

Color bar:

TV-picture with
Farbbalken ON

When color bar is ON then and datas will be sent to the module then the Farbbalken
will be switched off

Following configurations have to be done.

18

Hermann - Petersilge - Straße 1

D-07422 Bad Blankenburg

Phone: ++ 49 (0) 36 74 1 / 60 - 0

Telefax: ++ 49 (0) 36 74 1 / 60 - 100

www.blankom.de

BLANKOM Antennentechnik GmbH

·

·

·

Germany

Summary of Contents for 9650.03

Page 1: ...tersilge Stra e 1 D 07422 Bad Blankenburg Phone 49 0 36 74 1 60 0 Telefax 49 0 36 74 1 60 100 www blankom de BLANKOM Antennentechnik GmbH Germany Manual Headend Controller HCB 100 blue 9650 03 Changes...

Page 2: ...the HEADEND CONTROLLER 3 4 3 Manual start of NIT distribution 3 4 4 Timer Time controlled switching 3 4 5 Adjustment of Date Time 3 4 6 Cold stard of individual single modules 3 4 7 Change of User ID...

Page 3: ...n of your desktop and then call up System operation 1 1 WINDOWS XP Confirm LAN connection with douple click continue at page 4 3 Hermann Petersilge Stra e 1 D 07422 Bad Blankenburg Phone 49 0 36 74 1...

Page 4: ...Subnet mask The IP Address of the PC Laptop has to be different last two figures of the IP Address of the HCB 100 The Subnet mask can be entered as shown in the above example NO entries for Gateway D...

Page 5: ...r desktop and then call up System operation via Adjustments Confirm LAN connection with douple click continue at page 4 Hermann Petersilge Stra e 1 D 07422 Bad Blankenburg Phone 49 0 36 74 1 60 0 Tele...

Page 6: ...the PC Laptop has to be different last two figures of the IP Address of the HCB 100 The Subnet mask can be entered as shown in the above example NO entries for Gateway DNS necessary NOTICE Select TCP...

Page 7: ...nnections Select No connections Please disconnect the access to a Proxyserver for direct connection of the HCB 100 with PC Laptop 2 1 Microsoft Internet Explorer Please restart the PC Laptop after all...

Page 8: ...orrect You now can save secure the operation via a password Selecting the configuration Automatic Login allows i Login without password entry see 3 4 2 3 Working with the Headend Controller HCB 100 3...

Page 9: ...has been deleted You will be automatically forwarded to the Selcetion Menu Selection of desired Headend overview table see 3 2 Selection of Adjustments and Configurations see 3 3 9 Hermann Petersilge...

Page 10: ...s you to the operation overview of the respective module The first line horizontaly here 02 and 03 displays the line addresses of the Bus Extender Power supply BEB 100 The fist line verticaly here 01...

Page 11: ...tatus of the desired module Selecting RESET will disconnect switch off the desired module for 8 seconds The operating status of the desired module will be called up and displayes Ouput attenuation Sel...

Page 12: ...he serial n of the respective module Displays all setting adjustment opportunities of the entire headend or for individual modules Displays the IP number the current software of the Headend Controller...

Page 13: ...itional NIT datas a a a a Example NIT Rack A NIT Rack B HCB 100 with 32 x STB 606 OFF OFF a HCB 100 Rack A with 16 x STB 606 EIN OFF a HCB 100 Rack B with 16 x STB 606 OFF ON a Maxl 32 NIT Datas of th...

Page 14: ...eters values into the timer has to be done in the sequence of the operator interface of the respective module see page 17 for the sequences of the module Upper and lower cases have as well as the inpu...

Page 15: ...ml operation surface e g Operating status ON or OFF This menu is for the configuration of time controlled switching and will only be displayed when the Timer Mode is activated Example 1 Special case S...

Page 16: ...indow n Also the desired switchtimes for the switchover of the desired programs have to be selected special configuration for Antenne Bayern Name Antenne Bayern SAT IF 1548 ServiceID 170 Service Type...

Page 17: ...4 will be switche OFF at 20 00 hrs Switching condition channel 1 ON Programm HSE Output frequency 503 25 MHz K25 Only the active channel has to be selected for this configuration No further entries ne...

Page 18: ...The adjustments of the input parameters will be overtaken without a reset see tabel page 20 1 selection box 8 selection box Example for an Einstellbox Address Switchtime Parameter Werte Parameter List...

Page 19: ...F signal C LINE Farbbalken bernahme STB 1x1 920x xx SDB 209 9802 01 STB 2x1 STC 291 981x xx 9609 xx STB 607 9880 01 TTB 5x1 TTC 591 982x xx 9601 xx UCB 1x6 919x 01 CCB 1x1 TCB xx1 923x xx 92xx xx CTB...

Page 20: ...NOTICE Display of the date for digital Transmodulators possible only from sofware version V1 68 of the MPEG Module 3 4 5 Adjustment of Date Time 3 4 6 Cold start of single modules Entry of the sytste...

Reviews: