The appliance is set up to operate with the gas specified on the gas type label pla-
ced on the back of the appliance.
When the type of gas available does not correspond to that for which the appliance
is set up, replace the corresponding injectors (provided), being careful to put on the
new data label (provided) and remove the old one.
To perform these operations the qualified installer will follow the indications given in
the "Adaptation to the various types of gas" section. For safer operation make sure
that the supply pressure respects the values given in the "Table of burner and injec-
tor characteristics".
If installing for use with propane gas, ensure an AGA Approved gas regulator suita-
ble for a supply pressure of 2.75kPa is part of the gas tank supply and the test point
pressure is adjusted to 2.75kPa.
Once the appliance has been installed, make sure that the gas pipe is neither squa-
shed or damaged by moving parts.
Before Leaving - Check all connections for gas leaks with soap and water. DO NOT
use a naked flame for detecting leaks. Ignite all burners both individually and sepa-
rately to ensure correct operation of gas valves, burners and ignition. Turn gas taps
to low flame position and observe stability of the flame for each burner individually
and separately. When satisfied with the operation of the cooker, please instruct the
user on the correct method of operation. In case the appliance fails to operate cor-
rectly after all checks have been carried out, refer to the authorised service provider
in your area.
Adaptation to different types of gas
• remove the grids
• remove the burners caps and burner heads
• with a 7 mm socket spanner unscrew and remove the injec-
tors.
• replace the injectors with those supplied corresponding to the
gas available (see burner and injector characteristics Table)
• replace the various parts proceeding in reverse.
When converting from Natural Gas to Propane ensure that the
NG regulator is removed and replaced with the Test Point
Instructions for Installation
To adapt the appliance to a gas different from that for which
it was set up (see gas type label inside the warming
compartment door) proceed as follows: