background image

Power on 

Default displevy

Press and hold “Set”

Display “P1”or“P2” 

Display corresponding value

Press “Set”

Press “Stop”

End

Press “Open” or “Close” to adjust value

Press “Open” or “Close” to 

switch between “P1”&“P2” 

Warning!     Resetting should be operated by a qualified person.

BLANCO

14

Greek Gods are at your command

Summary of Contents for Cyble ULTRA

Page 1: ...FAST INSTALLATION MANUAL ROAD BARRIER Demeter Cyble ULTRA www blancoautomation com BLANCO...

Page 2: ...perly maintained Ground wire and current breaker MUST be connected Power MUST be cut off when performing installation or maintenance When power outage power MUST be cut off before using the manual rel...

Page 3: ...f the Machine C Main Components of the Motor A Close to Right B Close to Left Boom Spring Motor Boom Holder Base Plate Bearing Holder Balance Armr Manual Release Handle Optical Encoder Limits Fig 1 Fi...

Page 4: ...arking lot management system infrared sensor radar etc D Product contains multiple limit protection functions to keep a long life time 3 Specification Rated Power 240W 220V 10 50 60Hz 110V 10 50 60Hz...

Page 5: ...tom of the Cabinet inside Mark out the boreholes for Expansion Bolts Fig 3 L and W according to the Fixed Bars Move away the cabinet Use an electric drill with 21mm to drill the boreholes The depth of...

Page 6: ...oom holder to horizontal position Fig 4 Loosen the screws Move the springs away from springs support 4 2 1 Loosen the Screws and move the spring s away from the Spring Support Fig 4 Fig 5 Boom Holder...

Page 7: ...o Fig 6 4 2 4 Fix the Boom Support on the ground Adjust the height as the Rubber pad touches the boom when the boom is at horizontal position Fig 7 Fig 6 Outer boom holder Fig 7 Rubber pad Adjust heig...

Page 8: ...ight if it is not necessary If the boom length or weight must be changed e g adding a Stop Sign on the boom the balance must be adjusted by a qualified service person 5 2 1 Remove the screws on the Ca...

Page 9: ...he nut clockwise if the weight increased Loosen the nut counter clockwise if the weight decreased When adjusting all nuts should be turned at the same cycles in order to avoid the unevenly distributed...

Page 10: ...to 60 If the boom moves towards Open Status the Spring Nut should be loosened or reduce the number of springs If the boom moves toward Close Status the Spring Nut should be tightened or increase the...

Page 11: ...ing power outage turn the Manual Release towards Open Status to open the Automatic Boom Barrier Fig 11 6 Operating Instructions Fig 11 Close Open Close Status Linkage Nuts Adjustable Linkage Main Link...

Page 12: ...nal Stop External Close External Open Loop Detector Live Null GND Motor White Wire Motor Red Wire Motor Blue Wire External Power V External Power V LED LED Blue White Black Brown Optical Counter Red W...

Page 13: ...mit Adjusting 8 1 Optical Counter Disk 8 2 Open Close Limits For easy understanding we assume the value of P1 and P2 with 6 on the Control Board means the boom at vertical and horizontal position Fig...

Page 14: ...en and close the boom once to see whether the boom is vertical and hori zontal to the ground If so no adjustment is needed Otherwise follow the steps below to set the value of P1 and P2 P1 P2 Fig 14 B...

Page 15: ...splay P1 or P2 Display corresponding value Press Set Press Stop End Press Open or Close to adjust value Press Open or Close to switch between P1 P2 Warning Resetting should be operated by a qualified...

Page 16: ...99s Default 00 Means auto close function disabled 00 Normal Mode Default 01 Counting Mode 00 Normal Mode Default 01 Stay OPEN 01 Stay Light on when open to limit Default 00 Light out when open to limi...

Page 17: ...ower on Shortly press Set Display 77 Display 77 or 81 Press Set 79 Function Parameter 81 Timer Parameter Press Stop End Press Open or Close to change corresponding value Press Open or Close to change...

Page 18: ...light on and till go out Now all codes of transmitters which had been learnt are cleared 11 Error Codes Remove the Object that Blocks the Photo Beam Remove the Object that Block the Air Wave Optical...

Page 19: ...at middle position Spring force is not balance Readjust the balance Refer to Fig 15 See page 10 Reset Low power voltage Incorrect Linkage adjustment Incorrect Limits setting The Lock Flat Key between...

Page 20: ...BLANCO...

Reviews: