10
INSTALLATION
FIG. 3
TECHNICAL INFORMATION FOR THE INSTALLER
This appliance shall be installed only by authorised personnel and in accordance with the manufacturer’s
installation instructions, local gas fitting regulations, municipal codes, electrical wiring regulations, AS 5601 -
Gas Installation and any other statutory regulations.
Ventilation must be in accordance with AS 5601 - Gas Installation. In general, the appliance should have
adequate ventilation for complete combustion of gas, proper flueing and to maintain temperature of
immediate surroundings within safe limits.
The wall and bench surfaces must be capable of sustaining temperatures of 75 °C.
All laminates, fixing adhesive and surfacing materials should be certified suitable for this temperature.
INDICATIONS FOR INSTALLATION
●The device is designed to remain operational for less than 24 h (non-permanent operating system). When
this limit is reached, a regulation stoppage occurs so the device can check its efficiency.
●This automatic device is a safety device and must not be altered. Interference with this device will eliminate
any responsibility by the manufacturer and invalidate the warranty.
●Observe the national and European standards applicable (e.g., EN 60335-1/EN 50165) in relation to
electrical safety.
●Before entry into operation, check the wiring carefully: incorrect wiring may damage the device and
jeopardise the safety of the system.
●Connect and disconnect the hob only after cutting off the electricity supply.
●Avoid exposing the device to drops of water.
●Avoid laying the valve wires along with the high voltage wires of the ignition transformer.
●Ensure that there is nothing on the hob, particularly on the area of the control panel, before switching on.
●After switching on the hob, wait a few seconds to complete the automatic calibration procedure of the
control panel.
●In the event of a “partial” short circuit or insufficient insulation between the line and earth, the voltage on the
sensor electrode may be reduced so much that it causes the device to lock, due to the impossibility to
sense the flame signal.
●The extra low voltage (ELV) circuit is not safe to touch (only main insulation in compliance with
EN 60730-1), so the installation must guarantee the level of protection against electric shock equivalent to
double insulation for the user interface.
A
B
C
D
E
5F (860)
833
475
62.5
62.5
55 min.
COMPLY WITH THE DIMENSIONS
CAUTION:
the installer shall test the appliance before
leaving. Test the safety operation of the
ignition system on all burners individually
and combined.