INSTRUCTIONS FOR THE INSTALLER
POSITION (fig. 13)
The appliance should be positioned in good light
and free from draughts. Any adjoining wall surface
situated within 200 mm from the edge of any
hob burner must be a suitable non-combustible
material for a height of 150 mm for the entire
length of the hob. Any combustible construction
above the hotplate must be at least 750 mm above
the top of the burner and no construction shall be
within 450 mm above the top of the burner.
Where a combustible surface adjacent to the
cooker is less than 200 mm from the nearest
burner it may be protected by a non-combustible
protective layer in accordance with AS5601. The
protection must ensure the surface temperature
of the combustible surface does not exceed 65º
C above ambient.
LEVELLING THE COOKER
•
Adjustable feet, This model has adjustable
feet which can go from a heght of 870 -
930mm( excluding splashback of 60mm)
depending on how you adjust them.
•
Backguard. The cookers which are
equipped with this accessory, leave
the factory with this part inserted inside
the packaging. In order to install the
backguard, it is necessary to loosen the
screws positioned on the back of the hob
and then to fix the backgaurd as indicated
in figure 16.
OVERALL DIMENSIONS
(fig. 14)
870 - 930H x 900W x 600D mm
It is essential to check dimensions of physical
product when measuring for installation and
before doing any cut outs
.
Summary of Contents for BFD9054WX
Page 1: ...Instruction Manual for BLANCO 90cm Freestanding Cooker BFD9054WX 461308250_001 10 2013 ...
Page 10: ...10 ...
Page 32: ...32 TECHNICAL FEATURES WIRING DIAGRAM COOKER BFD9054WX ...
Page 33: ...33 We appreciate your feedback Please review our products on www blanco australia com ...
Page 34: ...34 ...
Page 36: ......