Blancett QUIKSERT Operation & Installation Manual Download Page 16

16  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8635 Washington Avenue • Racine, Wisconsin 53406 

Technical Toll-Free:  877.722.4631   

Sales Toll-Free:  800.235.1638  

Phone: 262.639.6770 • Fax: 262.639.2267 

www.blancett.com

 

 

Form: QuikSert Manual 

Revision 03/06

 

Summary of Contents for QUIKSERT

Page 1: ...SERT FLOW METER OPERATION INSTALLATION MANUAL 8635 Washington Ave Racine Wisconsin 53406 Technical Toll Free 877 722 4631 Sales Toll Free 800 235 1638 Phone 262 639 6770 Fax 262 639 2267 www blancett...

Page 2: ...tructions 6 Operational Startup 9 Calibration 9 Troubleshooting 10 Part Numbering Information 11 Repair Kit Information 12 Statement of Warranty 13 Note Blancett reserves the right to make any changes...

Page 3: ...oy and tungsten carbide Fluid moving through the turbine flow meter causes the rotor to turn at a speed proportional to the flow rate The rotor blade cuts the magnetic field of the magnetic pick up wh...

Page 4: ...Vibration and Shock Severe mechanical vibration may decrease service life of the meter Filtration Install a strainer upstream of meter if small particles are present Note Pressure in excess of allowa...

Page 5: ...5 ILLUSTRATIONS FIGURE 2 Models B132 050 through B139 900 FIGURE 1 Models B131 038 through B131 100...

Page 6: ...piping with the pick up facing upward However the meter will function in any position The liquid that is to be measured must be free from any large par ticles that may obstruct rotation of the rotor...

Page 7: ...r accuracy may be affected Piping should be the same size as the flange size Do not locate the flow meter or connection cable close electronic motors transforming sparking devices high voltage lines o...

Page 8: ...8 FIGURE 3 Meter installation utilizing a bypass line FIGURE 4 Meter installation without utilizing a bypass line...

Page 9: ...ream valve to provide the required flow rate through the meter Note The downstream valve may be used as a control valve CALIBRATION The meter is calibrated on water at the factory and tagged with a K...

Page 10: ...orn bearing Viscosity higher than calibrated Clean meter and add filter Clean meter and add filter Recalibrate monitor Erratic system indica tion meter alone works well remote monitor application only...

Page 11: ...11 APPENDIX B PART NUMBER INFORMATION...

Page 12: ...12 APPENDIX C REPAIR KIT INFORMATION...

Page 13: ...must be thoroughly cleaned and any proc ess chemicals removed before it will be accepted for return The purchaser must determine the applicability of the product for its desired use and assumes all r...

Page 14: ...14 NOTES...

Page 15: ...15...

Page 16: ...16 8635 Washington Avenue Racine Wisconsin 53406 Technical Toll Free 877 722 4631 Sales Toll Free 800 235 1638 Phone 262 639 6770 Fax 262 639 2267 www blancett com Form QuikSert Manual Revision 03 06...