Blancett QUIKSERT Operation & Installation Manual Download Page 13

13  

 

STATEMENT OF WARRANTY 

 

Blancett Flow Meters, Division of Racine Federated, Inc. warrants to 
the end purchaser, for a period of one year from the date of shipment 
from the factory, that all flow meters manufactured by it are free from 
defects in materials and workmanship.  This Warranty does not cover 
products that have been damaged due to defects caused by abnormal 
use, misapplication, abuse, lack of maintenance, modified or im-
proper installation.  Blancett’s obligation under this warranty is lim-
ited to the repair of replacement of a defective product, at no charge 
to the end purchase, if the product is inspected by Blancett and found 
to be defective. Repair or replacement is at Blancett’s discretion.  A 
return goods authorization (RGA) number must be obtained from 
Blancett before any product may be returned for warranty repair or 
replacement.  The product must be thoroughly cleaned and any proc-
ess chemicals removed before it will be accepted for return. 
 
The purchaser must determine the applicability of the product for its 
desired use and assumes all risks in connection therewith. Blancett 
assumes no responsibility or liability for any omissions or errors in 
connection with the use of its products.  Blancett will under no cir-
cumstances be liable for any incidental, consequential, contingent or 
special damages or loss to any person or property arising out of the 
failure of any product, component or accessory.  
 
All expressed or implied warranties, including 

the implied warranty 

of merchantability and the implied warranty of fitness for a par-
ticular purpose or application are expressly disclaimed 

and shall 

not apply to any products sold or services rendered by Blancett. 
 
The above warranty supersedes and is in lieu of all other warranties, 
either expressed or implied and all other obligations or liabilities.  No 
agent or representative has any authority to alter the terms of this war-
ranty in any way. 

 
 
 
 
 
 
 

Summary of Contents for QUIKSERT

Page 1: ...SERT FLOW METER OPERATION INSTALLATION MANUAL 8635 Washington Ave Racine Wisconsin 53406 Technical Toll Free 877 722 4631 Sales Toll Free 800 235 1638 Phone 262 639 6770 Fax 262 639 2267 www blancett...

Page 2: ...tructions 6 Operational Startup 9 Calibration 9 Troubleshooting 10 Part Numbering Information 11 Repair Kit Information 12 Statement of Warranty 13 Note Blancett reserves the right to make any changes...

Page 3: ...oy and tungsten carbide Fluid moving through the turbine flow meter causes the rotor to turn at a speed proportional to the flow rate The rotor blade cuts the magnetic field of the magnetic pick up wh...

Page 4: ...Vibration and Shock Severe mechanical vibration may decrease service life of the meter Filtration Install a strainer upstream of meter if small particles are present Note Pressure in excess of allowa...

Page 5: ...5 ILLUSTRATIONS FIGURE 2 Models B132 050 through B139 900 FIGURE 1 Models B131 038 through B131 100...

Page 6: ...piping with the pick up facing upward However the meter will function in any position The liquid that is to be measured must be free from any large par ticles that may obstruct rotation of the rotor...

Page 7: ...r accuracy may be affected Piping should be the same size as the flange size Do not locate the flow meter or connection cable close electronic motors transforming sparking devices high voltage lines o...

Page 8: ...8 FIGURE 3 Meter installation utilizing a bypass line FIGURE 4 Meter installation without utilizing a bypass line...

Page 9: ...ream valve to provide the required flow rate through the meter Note The downstream valve may be used as a control valve CALIBRATION The meter is calibrated on water at the factory and tagged with a K...

Page 10: ...orn bearing Viscosity higher than calibrated Clean meter and add filter Clean meter and add filter Recalibrate monitor Erratic system indica tion meter alone works well remote monitor application only...

Page 11: ...11 APPENDIX B PART NUMBER INFORMATION...

Page 12: ...12 APPENDIX C REPAIR KIT INFORMATION...

Page 13: ...must be thoroughly cleaned and any proc ess chemicals removed before it will be accepted for return The purchaser must determine the applicability of the product for its desired use and assumes all r...

Page 14: ...14 NOTES...

Page 15: ...15...

Page 16: ...16 8635 Washington Avenue Racine Wisconsin 53406 Technical Toll Free 877 722 4631 Sales Toll Free 800 235 1638 Phone 262 639 6770 Fax 262 639 2267 www blancett com Form QuikSert Manual Revision 03 06...

Reviews: