This manual is intended to help you get the B2800 flow monitor up and running quickly 

MPOOTANT

I

Read this manual carefully before attempting any installation or operation. Keep the manual accessible for future reference. 

UNPACKING AND INSPECTION

Upon opening the shipping container, visually inspect the product and applicable accessories for any physical damage such 

as scratches, loose or broken parts, or any other sign of damage that may have occurred during shipment 

OTEE:

N

If damage is found, request an inspection by the carrier’s agent within 48 hours of delivery and file a claim with the 

carrier

  

A claim for equipment damage in transit is the sole responsibility of the purchaser

 

SAFETY

Terminology and Symbols

 

Indicates a hazardous situation, which, if not avoided, is estimated to be capable of causing death or 

serious personal injury 

 

Indicates a hazardous situation, which, if not avoided, could result in severe personal injury or death 

 

Indicates a hazardous situation, which, if not avoided, is estimated to be capable of causing minor or 

moderate personal injury or damage to property  

Considerations

The installation of the B2800 monitor must comply with all applicable federal, state, and local rules, regulations, and codes 

EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.

AVERTISSMENT 

RISQUE D’EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CEMATÉRIEL INACCCEPTABLE POUR LES 

EMPLACEMENTS DE CLASSE I, DIVISION 2.

DO NOT CONNECT OR DISCONNECT EITHER POWER OR OUTPUTS UNLESS THE AREA IS KNOWN TO BE NON-

HAZARDOUS.

AVERTISSMENT 

RISQUE D’EXPLOSION. NE PAS DÉBRANCHER TANT QUE LE CIRCUIT EST SOUSTENSION, À MOINS QU’LL NE S’AGISSE 

D’UN EMPLACEMENT NON DANGEREUX.

MPOOTANT

I

Not following instructions properly may impair safety of equipment and/or personnel.

Scope of This Manual

Page 3 

March 2017 

DSY-PM-00278-EN-03

Summary of Contents for B2800 SERIES

Page 1: ...Flow Monitor B2800 Panel Mount Standard DSY PM 00278 EN 03 March 2017 User Manual...

Page 2: ...5 Modes 5 Programming 6 Programming Mode 6 Run Mode 7 Additional Scaling Parameters 8 Flow 4 mA Setting 8 Flow 20 mA Setting 8 4 20 mA Calibration 8 4 20 mA Test 8 Battery Replacement 9 Additional Inp...

Page 3: ...serious personal injury Indicates a hazardous situation which if not avoided could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be ca...

Page 4: ...umeric display provides for selectable units viewing in run mode and prompts for variables in program mode The display can show rate total or alternate between both rate and total Figure 1 B2800 Panel...

Page 5: ...0 panel mount flow monitor Buttons MENU Switches to PROGRAM mode UP Scrolls forward through the parameter options and increments numeric variables RIGHT Scrolls backward through the parameter options...

Page 6: ...and the bore size are different For example many of the one inch NPT turbines have bore sizes that range from 3 8 1 in Be sure to use the correct bore size or the meter will report incorrect flows and...

Page 7: ...e Initially the password is set to all zeros and any user can modify the parameter settings in PROGRAM mode To change the password enter any four digit code Press UP to increment the digit and RIGHT t...

Page 8: ...the 4 20 mA output The 4 mA setting is typically between 35 50 To set the 4 mA value connect an ammeter in series with the loop power supply At the 4MA OUT prompt press UP to increment and RIGHT to de...

Page 9: ...ct closure input pulse Since most Blancett turbine flow meters utilize a magnetic pickup the B2800 flow monitor is shipped configured for magnetic pickup input To change to a contact closure input rem...

Page 10: ...perature Drift 50 ppm C maximum Mounting Style Panel Mount 3 6 inch 3 6 inch Opening NEMA 4 front only Environmental Operating Temperature 22 158 F 30 70 C Humidity 0 90 Non condensing Inputs Type Mag...

Page 11: ...s reading constantly This is usually an indication of external noise Keep all AC wires separate from DC wires Check for large motors close to the meter pickup Check for radio antenna in close proximit...

Page 12: ...tandard The Americas Badger Meter 4545 West Brown Deer Rd PO Box 245036 Milwaukee WI 53224 9536 800 876 3837 414 355 0400 M xico Badger Meter de las Americas S A de C V Pedro Luis Ogaz n N 32 Esq Ange...

Reviews: