background image

Blagdon Force-Hybrid Pumps

 are centrifugal pumps with a magnetic impeller 

movement driven by a watertight asynchronous motor. They require minimum 

cleaning, only periodic cleaning of the pre-filter cage and impeller is necessary.

Monthly Maintenance/Opening the cage

Remove cage and impeller cover, wash all parts thoroughly with fresh water.

 

Warning -

 Failure to carry out routine maintenance leaving the pump  

 

under reduced or no flow conditions for long periods (i.e. blocked    

 

outlet, pipework filter cage) will result in a shorter pump life and will  

 

invalidate the guarantee.

MAINTENANCE & CLEANING

MAINTENANCE & CLEANING

Annual Maintenance/Removing the impeller

First follow the Monthly Maintenance/Opening the cage steps.

Remove the impeller and wash all parts thoroughly with fresh water.

Dismantle pump and examine all parts for wear or damage, replacing any parts that 

show obvious wear and/or damage. (See getting to know your pump for parts/

description and replacement parts codes.) Particular care should be taken to examine 

the cable entry point and the cable; if there is any sign of damage the pump should be 

discarded.

Winter Storage

The pump can be run in the pond during the winter but care should be taken to 

ensure that it is fully immersed and cannot freeze solid. If the pump is not used 

during the winter, follow annual maintenance procedure and store frost-free in the 

house or garage until spring.

1

5

2

3

4

1

3

4

2

Turn both locks to 

unlock position

Turn impeller cover 

anti-clockwise to open

Depress button

Remove the two pump 

locating screws

Pull out the motor from the back page

Remove the impeller and wash 

all parts in clean water

Remove the four impeller 

chamber screws

Remove valve 
locater

Pull 
firmly 
apart

6

7

Reviews: