8

INSTALLATION

Electrical installation

The power supply must meet the specifications on the product.

The air pump is designed to be used with either a weather-proof cable connector 
or connected to the mains by means of a plug and socket.

The cores in the supply cable are coloured in accordance with the following code:

Brown = Live, Blue = Neutral, Green/Yellow = Earth

The electrical cable is permanently connected inside the air pump body.

If the supply cable is damaged the air pump must not be used.

Do not use the supply cable to lift the air pump, as this may cause damage.

For permanent installations to the mains supply, it is necessary to conform to the regulations of 
the local electricity authority and this would include the use of a metal or plastic conduit to  
protect the cable.

Attention has been drawn to the fact that the special rules may exist concerning the installation 
of your pond air pump (i.e. local building regulations). These air pumps must not be used in  
swimming pools, or areas where people are in contact with the water.

Always disconnect and isolate the product from the mains electricity supply whilst the equipment 
is being installed, repaired, maintained or handled. Consult a qualified electrician if you are in  
any doubt about wiring this product to the mains supply.

WARNING -

 A Residual Current Device (RCD), also known as the Residual Current 

Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed 
in the supply circuit. A means of disconnection from the supply having a contact 
separation of at least 3mm in all poles must be incorporated in the fixed wiring.

WARNING - 

The air pumps must not be submerged in the pond, they are for 

external installation only.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children 
without supervision.

Summary of Contents for 1056199

Page 1: ...www blagdonwatergardening co uk www interpetcentral com Pond Oxygenator Single Twin Four...

Page 2: ...lacing the air stones directly into the filter chambers beneficial filter bacteria will be encouraged to grow This will improve the efficiency of a pond filter as well as improve fish health Aeration...

Page 3: ...ocation 9 Connecting air line and air stones 9 Maintenance 10 Replacing the intake filter 10 Replacing the Outlet O Ring 10 Replacing the diaphragm flapper valve Pond Oxygenator Single Twin Four 11 Tr...

Page 4: ...2 Pond Oxygenator Single Parts Diagram GETTING TO KNOW YOUR POND OXYGENATOR 1 2 3 4 5 10 11 12 13 14 9 7 8 6...

Page 5: ...ription Spare Code 1 Pond Oxygenator Single Lid N A 2 Cable Gland N A 3 Air Filter Pad Holder 1055940 4 Pond Oxygenator Single Lid O ring 1055940 5 Air Filter Pad Holder O ring 1055940 6 Pond Oxygenat...

Page 6: ...Pond Oxygenator Twin Parts Diagram GETTING TO KNOW YOUR POND OXYGENATOR 4 1 2 3 4 5 6 8 14 16 15 7 9 13 10 11 12...

Page 7: ...nator Twin Motor N A 7 Pond Oxygenator Twin Base N A 8 Pond Oxygenator Twin Rubber Feet 1055941 9 Pond Oxygenator Outlet Bridge Screws N A 10 Pond Oxygenator Twin Diaphragm and Valve Screw Clamp N A 1...

Page 8: ...Pond Oxygenator Four Parts Diagram GETTING TO KNOW YOUR POND OXYGENATOR 6 1 2 3 4 5 6 8 14 15 16 7 9 13 10 11 12...

Page 9: ...tor Four Motor N A 7 Pond Oxygenator Four Base N A 8 Pond Oxygenator Four Rubber Feet 1055942 9 Pond Oxygenator Four Outlet Bridge Screws N A 10 Pond Oxygenator Four Diaphragm and Valve Screw Clamp N...

Page 10: ...ed in swimming pools or areas where people are in contact with the water Always disconnect and isolate the product from the mains electricity supply whilst the equipment is being installed repaired ma...

Page 11: ...sible life span for all replaceable parts e g diaphragms and flapper valves Ideally all outlets should have an air line and air stone connected this will give your pond maximum aeration and ensure tha...

Page 12: ...he outlet O ring all sizes 1 Remove base screw rubber caps and unscrew the base screws 2 Lift off air pump lid 3 Disconnect the air line in between diaphragm flapper valve and the metal outlet 4 Unscr...

Page 13: ...even Follow steps 1 to 5 in reverse order to reassemble Step Four Remove old diaphragm and flapper valve assembly replace with new Step Six Remove old diaphragm and flapper valve assembly replace with...

Page 14: ...and replace any blocked air stones Replace blocked or dirty air filter pads Check diaphragm and flapper valve assembly for wear and tear replace as necessary No air output pump stopped Check the power...

Page 15: ...anship for 3 years from the date of purchase under normal usage The guarantee DOES NOT APPLY in case of improper use negligence lack of maintenance or accidental damage either to the pump controller o...

Page 16: ...rch and development that ensures excellent product performance and value for money for our customers Our products are brought together with half a century of expertise and knowledge so you can be assu...

Reviews: