HIGH TEMPERATURE INSTALLATIONS
In situations where the temperature of the fluid to be pumped is likely to exceed 80°C, a high temperature pump code must be specified. This
is signified using an ‘X’ in the last part of the pump code as shown.
“XTS” in place of “TTS”. Reference Pump Code matrix on page 6
This indicates the following specification amendments :-
All seals and o-rings will be changed from Buna-N to Viton. Any gaskets will be changed to a higher temperature spec. Diaphragm shaft
bushes will be changed from plastic to metal, back-up diaphragms and any bumpstops will be changed to Viton.
Refer to main table on page 8 for quantities / pump.
Flanged Manifolds
Suction Lift Installation
Flooded Suction Installation
Submerged Installation
Exhaust Safety :-
When a diaphragm fails during operation, pumped liquid can enter and contaminate the air side of the pump. If diaphragm failure is not
severe, i.e. a small split or hole, then the pump can continue to run, with air being forced into the product being pumped. If however the
failure is more serious, then the pump may stop, with fluid or fumes being expelled through the exhaust. Under these conditions it is
recommended that the exhaust is piped away to a safe area. In standard suction lift conditions this can simply be done by piping from the
exhaust connection to a safe area. Multiple installations can be piped to a common connection, then to a safe area. In flooded suction
conditions the exhaust must be taken to a point higher than the fluid level to prevent any siphoning away. In submerged conditions ensure
exhaust is piped away above fluid level.
In all conditions ensure exhaust outlet is not expelling across a non-conductive surface. The exhaust must not be placed less than 100mm
from any non-conductive surface, as this may generate a propagating brush discharge resulting in a possible ignition source.
Exhaust Safety Instructions
FLANGED MANIFOLD PART NOS.
SUCTION
MANIFOLD
40
ANSI 150
PN16
VIRGIN PTFE
25-196
25-200
CONDUCTIVE PTFE
25-198
25-202
DISCHARGE
MANIFOLD
17
ANSI 150
PN16
VIRGIN PTFE
25-197
25-201
25-199
25-203
CONDUCTIVE PTFE