16
SAFETY DEVICES
AC Outlet
Your generator is equipped with an AC circuit
breaker, see page 14. If this is OFF, then the
generator will produce NO POWER.
To restart the power supply;
1. Remove the appliance.
2. Stop the generator, see page 14.
3. Wait 2 minutes.
4. Turn the AC circuit breaker ON.
5. Start generator.
6. Appropriately dispose of the fuel.
7. If the AC circuit breaker trips the attached
appliance is either faulty or the appliances
required power is greater than the
generators output.
MAINTENANCE INFORMATION
If scheduled maintenance is NOT carried out then
this will void your warranty. Use the Service Log
on page 20 to keep track of the regular servicing.
Ensure that the authorised service agent has
dated, signed and stamped this log to ensure your
warranty is not void.
Fuel Tank Filter, Pic. 9
The fuel tank
fi
lter should be checked every time
you
fi
ll up the fuel tank. If dirty, replace. Your
fuel tank
fi
lter should be replaced every 50 hours
(operation) or every 3 months, which ever occurs
fi
rst or whenever considered necessary.
To check or replace the fuel tank
fi
lter;
1. Remove the fuel tank cap.
2. Remove the fuel tank
fi
lter.
3. If dirty replace fuel tank
fi
lter before using the
generator.
4. Push new fuel tank
fi
lter into the top of the fuel
tank.
5. Replace the fuel tank cap.
Fuel Line Filter
The fuel line
fi
lter should be replaced every 50
hours (operation) or every 3 months, which ever
occurs
fi
rst or whenever considered necessary.
This must be replaced by an authorised service
agent. This servicing must be carried out as noted
above or your warranty will be void.
PIC. 9
Fuel tank
fi
lter under
fuel tank cap