Blackridge BRG1700 User Manual Download Page 8

8

9

SpeciFic SAFeTY 

iNSTRUcTioNS

Warning!

 Do not use the generator in areas 

where there is a risk of explosion or fire from 
combustible materials.  The sparks possibly 
caused when using this generator may ignite 
combustible materials as well as flammable 
liquids, paint, varnish, petrol, flammable gases 
and dust of an explosive nature.  As a precaution 
it is recommended that you consult an expert on 
a suitable fire extinguisher and its use. Ensure 
that the work area is kept clear of combustible 
materials.

Warning!

 Do not use the generator indoors or in 

confined spaces where exhaust gases, smoke or 
fumes could reach dangerous concentrations.
•  Never connect this generator to a second 

generator.

•  Never connect this generator to Commercial or 

Domestic power supply.

•  Always use the generator in an open well 

ventilated area.

•  Unit will become hot during use.  Please keep 

generator at least one metre (1m) away from 
buildings, other equipment, pedestrian areas or 
flammable materials.

•  Never pull the re-coil starter once the generator 

engine has started.  Any damage caused will 
not be covered by warranty.

•  Never start or stop the generator with any 

appliances attached.

•  Ensure the generator has stopped before 

servicing, or lubricating etc.

•  Do not attempt to modify the generator, guards 

or the supplied accessories in any way.

•  Do not touch the exhaust.  This can become 

very hot during operation and can cause serious 
burns.

•  Always check the generator for damaged parts 

or fuel leaks, ensure these are fixed before 
using it.

•  Never refuel while smoking or in the vicinity of 

an open flame.

•  Always wear safety eye wear, ear and breathing 

protection when operating or refuelling the 
generator.

•  To avoid a fire if you spill fuel while refuelling, 

clean up before starting the generator.

•  Never operate or store the generator on its 

side, ALWAYS operate or store in an upright 
manner on firm, solid ground.

•  Your generator is factory set, NEVER attempt 

to speed it up as this could endanger the user 
and damage the generator and/or attached 
appliances.

•  Never operate the generator in damp, wet or 

flooded conditions.

•  Before plugging appliances into the generator 

allow it to run up to full speed.

•  If the generator makes an unfamiliar sound or 

vibrates excessively, switch the generator ‘OFF’ 
immediately. Investigate the possible cause or 
consult your authorised service agent.

•  Do not use ANY type of coolant on the 

generator as a fatal electric shock could occur.

•  Never use coolant in the generator as damage 

may occur.

•  Do not touch the generator with wet hands as 

this may cause electrocution.

•  Never use your generator on highly conductive 

surfaces e.g. Steel walk ways, metal roof or 
metal bench, as this could cause an electric 
shock.

•  Always operate your generator at least two (2) 

metres away from conductive surfaces.

•  Locate this generator in a convenient place, 

avoid using long extension leads.

•  If an extension lead is used, avoid leaving it 

where it may be damaged by pedestrian or 
vehicular traffic or cause a trip and fall hazard.

•  Always observe normal safety precautions with 

ALL appliances used with this generator.

•  Never transport the generator with fuel in the 

tank.  ALWAYS empty the fuel tank.

•  All loads must be kept within the ratings stated 

on the name plate.  Overloading the generator 
will damage the unit or shorten its life.  This will 
not be covered under warranty.

•  Do not tamper or alter any parts as this may 

cause personal injury or damage the generator.

•  Always disconnect any loads before starting or 

stopping the generator.

•  When storing the generator always store in a 

secure well ventilated area.

•  Always store in an upright position. NEVER 

store or lay this generator on its side.

Summary of Contents for BRG1700

Page 1: ...02833 08 11 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 1700W Inverter Generator...

Page 2: ...ng fridges up to 200W Lighting up to 1250W Mobile phone i pod hand held games charging up to 1000W Never exceed 1500W in total when using multiple devices Section Page Contents 2 Suggested Application...

Page 3: ...omponents of similar quality grade and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather t...

Page 4: ...tion where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished parts may be us...

Page 5: ...generator with wet or damp hands as electric shock may occur Always ensure your generator is connected to ground i e Earthed with the supplied earth stake see page 13 BEWARE OF CHILDREN PETS Children...

Page 6: ...our generator use only a damp soft cloth NEVER use liquid or solvents of any type EXTENSION CORDS REELS Inspect extension cords periodically and replace if damaged Never use damaged extension cord as...

Page 7: ...ction when using or refuelling generators Prescription glasses do not have safety lenses Footwear Where there is the risk of heavy objects or if there is a risk of slipping on wet or slippery floors s...

Page 8: ...before starting the generator Never operate or store the generator on its side ALWAYS operate or store in an upright manner on firm solid ground Your generator is factory set NEVER attempt to speed i...

Page 9: ...clean fresh unleaded petrol ULP Use a clean approved container to store your unleaded petrol ULP in before decanting into the fuel tank If contaminated dirty or old stale fuel is used any damage cause...

Page 10: ...bes 7 Recoil handle 8 Fuel Engine ON OFF lever 9 Earth lead attach point 10 240V AC Power outlet sockets 11 Output power green light 12 Output power overload red light 13 Low oil red light 14 Smart th...

Page 11: ...caution when checking the generator 1 Check that the fuel engine switch is OFF 2 Check that the spark plug lead is firmly attached to the top of the spark plug 3 Ensure that NO appliances are connect...

Page 12: ...hen filling with oil DO NOT TIP 5 Only fill oil to the top of the thread Pic 4 6 Ensure that the oil filler cap is screwed on tightly before attempting to start the generator WARNING Over filling the...

Page 13: ...emoving the Earth stake and wire Starting Your Generator Warning Never start your generator without earth stake attached or with smart throttle ON or electrical appliances or power leads attached 1 En...

Page 14: ...engaged then pull briskly This step may need to be repeated until generator engine starts this can take up to about 12 pulls WARNING Never pull the recoil once the engine has started Any damage caused...

Page 15: ...rtable television Up to 175W Portable television DVD Video combination player combination Up to 900W AC DC camping fridge Up to 200W Cooling fans Up to 800W Heating Up to 800W Radio CD player Up to 15...

Page 16: ...tch ON you will reduce the speed of the engine and the generator If a load is required the generator will automatically increase the speed of the engine and the generator Only turn the smart throttle...

Page 17: ...heck the oil level first Stopping Your Generator Important Before stopping the engine ensure ALL electrical appliances or power leads are unplugged from the generator Cooling Down Allow your generator...

Page 18: ...the access panel Pic 1 Item 5 page 10 3 Place a fuel resistant container under the discharge tubes see Pic 16 4 Loosen the bowl screw see Pic 16 5 Allow the fuel to drain into the container 6 Tighten...

Page 19: ...tank cap Fuel Line Filter The fuel line filter should be replaced every 50 hours operation or every 3 months which ever occurs first or whenever considered necessary This must be replaced by an author...

Page 20: ...ck or change oil 1 Remove access panel 2 Remove oil plug and check oil level refer page 10 for oil level Top up if required 3 To change oil do steps 1 and 2 then pour old oil into a suitable container...

Page 21: ...ossible no spark Check replace spark plug Generator is loaded on start up Remove appliance from generator Engine will not run Possible Cause Suggested Fix Fuel cap breather lever is OFF Turn fuel cap...

Page 22: ...0FCP 15 Rubber feet 84 BRG1700RF Spark plug 84 BRG1700SP Air filter element 84 BRG1700AF Socket 800 2 016 Oil bottle empty 800 2 018 Earth stake and lead 2500 1 035 23 Multi function display 84 BRG170...

Page 23: ...Check Adjust Fuel tank filter Spark plug Fuel line filter Air filter Oil Authorised Service Agent Name or Company Stamp Technician Date This Service is to be complete within 100 hours or 6 months of p...

Page 24: ...ed trademark of Smart Marketing Group Pty Ltd Technical Information Specifications Generator BRG1700 Output Voltage 240V AC 50Hz Continuous Power Rated 1700W 7 0 Amps Maximum Output 1 7Kva at power fa...

Reviews: