22.  Attach a new bearing cover gasket (26) and inboard 

bearing cover (27A) to the inboard head. Install the 
outboard bearing cover (27) and a new gasket to the 
outboard head. Make sure the grease fittings (76) on 
the bearing covers are accessible. Install and torque 
bearing cover capscrews (28) to 30 lbs ft (40.7 Nm). 

23.  On 2" models, slide the dirt shield (123A) over the shaft 

and push it firmly against the inboard bearing cover. 

24.  RELIEF VALVE ASSEMBLY 

a.  Insert the valve (9) into the relief valve bore of the 

casing with the fluted end inward. 

b.  Install the relief valve spring (8) and spring guide (7) 

against the valve. 

c.  Attach a new relief valve O-ring (10) and the valve 

cover (4) on the cylinder. 

d.  Screw the relief valve adjusting screw (2) with locknut 

(3) into the valve cover (4) until it makes contact with 
the spring guide (7). 

e.  After the relief valve has been adjusted, tighten the 

Locknut (3) and install the relief valve cap (1) and O-
ring (88) 

NOTICE: 

The relief valve setting MUST be tested and adjusted 
more precisely before putting the pump into service.  
Refer to "Relief Valve Setting and Adjustment" 

 

 

Operation without guards in place can 
cause serious personal injury, major 
property damage, or death. 

 

Do not operate 

without guard in 

place. 

25.  Reinstall coupling, shaft key, and coupling guards.  

26.  Refer to “Pre-Start Up Check List” and “Start Up 

Procedures” sections of this manual prior to restarting 
pump operation. 

 

 
 

 

Summary of Contents for XL2B

Page 1: ... inch 107 B01 107 B02 SAFETY DATA This is a SAFETY ALERT SYMBOL When you see this symbol on the product or in the manual look for one of the following signal words and be alert to the potential for personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or ma...

Page 2: ...ference If replacement parts are needed or if information pertaining to the pump is required this data must be furnished to a Blackmer representative TECHNICAL DATA 2 3 inch 4 inch Maximum Pump Speed 780RPM 640 RPM Maximum Operating Temperature 240 F 115 C Maximum Differential Pressure 150 psi 10 3 Bar Maximum Working Pressure 350 psi 24 1 Bar Technical Data is for standard materials of constructi...

Page 3: ...t elevated temperature provisions should be made to compensate for expansion and contraction of the pipes especially when long pipe lines are necessary Steel pipe expands approximately 3 4 1 9 cm per 100 feet 30 49 m per 100 F 37 8 C rise in temperature PUMP MOUNTING A solid foundation reduces noise and vibration and will improve pump performance On permanent installations it is recommended the pu...

Page 4: ...ry death or major property damage Hazardous pressure can cause personal injury or property damage Failure to relieve system pressure prior to performing pump service or maintenance can cause personal injury or property damage Hazardous pressure can cause personal injury or property damage Pumps operating against a closed valve can cause system failure personal injury and property damage Hazardous ...

Page 5: ... within the expected conditions Record pressures in the Initial Start Up Information section 3 Check for leakage from the piping and equipment 4 Check for overheating excessive noise or vibration of the pump reducer and motor 5 Check the flow rate to ensure the pump is operating within the expected parameters Record flow rate in the Initial Start Up Information section 6 Check the pressure setting...

Page 6: ...sure control valve XL series pumps are fitted with an internal pressure relief valve that bypasses back to the suction side of the pump Pumping volatile liquids under suction lift may cause cavitation Partial closing of the discharge valve WILL result in internal relief valve chatter and is NOT recommended For these applications install an external system pressure control valve and any necessary b...

Page 7: ... avoid possible entanglement in moving parts do not lubricate pump bearings gear reducer or any other parts while the pump is running NOTICE If pumps are repainted in the field ensure that the grease relief fittings 76A are functioning properly after painting Do NOT paint them closed Remove any excess paint from the fittings Pump bearings should be lubricated every one to twelve weeks AT MINIMUM d...

Page 8: ...or damage and replace as required c Repeat steps a and b on the opposite shaft end 6 Remove the head capscrews 21 Gently pry the head away from the casing using two large screwdrivers The head O ring should come off with the head assembly 7 Slide the head and O ring off the shaft The bearing 24 mechanical seal stationary seat and stationary O ring 153A 153D will come off with the head assembly a O...

Page 9: ...bottom vanes and push rods are installed carefully insert the non driven end of rotor and shaft into the casing d Install the remaining vanes into the top positions of the rotor 7 DISC 2 and 3 inch Models Install the disc 71 on the inboard side of the pump with the seal cavity facing outward and the disc relief hole located as shown in Figure 6 Figure 6 Disc Relief Hole Location 2 and 3 inch Model...

Page 10: ...he head capscrews to 30 lbs ft 40 7 Nm alternating between one side of the head and the other Frequently check that the shaft still turns freely If tight loosen the capscrews and repeat the procedure If the shaft continues to bind check for grease or dirt on the mechanical seal faces Figure 9 Locknut Assembly 20 LOCKNUT ADJUSTMENT It is important that the bearing locknuts 24A and lockwashers 24B b...

Page 11: ...uide 7 against the valve c Attach a new relief valve O ring 10 and the valve cover 4 on the cylinder d Screw the relief valve adjusting screw 2 with locknut 3 into the valve cover 4 until it makes contact with the spring guide 7 e After the relief valve has been adjusted tighten the Locknut 3 and install the relief valve cap 1 and O ring 88 NOTICE The relief valve setting MUST be tested and adjust...

Page 12: ...otor and brake windings to verify the integrity of the winding insulation and inspect all terminal box openings and wire connection areas to verify that all components are dry and free of corrosion Long Term Storage By taking special precautions problems such as seal leakage and reducer failure due to the lack of lubrication improper lubrication quantity or contamination can be avoided The followi...

Page 13: ...alphaolefin Oil FG Food Grade Oil NOTICE The Ambient Temperature is intended to be an operation guideline based upon the typical properties of all the lubricant The viscosity and other properties of the lubricant change based upon load speed ambient conditions and reducer operating temperatures The user should consult with their lubrication supplier NORD gear before considering changes in oil type...

Page 14: ...Liquids that set up when inactive OVERHEATING Probable Cause Corrective Action Continual full bypassing of the liquid Adjust the relief valve such that the pump will not bypass during normal operation WARNING Internal bypassing of liquid elevates the liquid temperature The internal bypass valve should only be used for brief periods and at differential pressures below 125 psi For extended periods o...

Page 15: ...rn vanes discs or rotor Bearing Worn or Damaged Loose or improperly installed piping Misalignment of pump and driver or bent shaft Pump base not properly mounted Insufficient Oil in the Gear Reducer POOR OR NO PRIMING Probable Cause Air leaks in the suction line Valve partially closed or other restriction in the suction line Damaged or worn pump parts Too much lift for the vapor pressure of the fl...

Page 16: ...cked cut or twisted Shaft at seal area damaged worn or dirty Excessive cavitation Mechanical seal faces cracked scratched pitted or dirty Ball bearings overgreased MOTOR OVERLOAD Probable Cause Horsepower of motor not sufficient for application Improper wire size wiring and or voltage to motor Misalignment in pump drive system Bearing locknuts adjusted improperly Excessive viscosity pressure or sp...

Reviews: