104-A00 page 2/16
SAFETY DATA
Hazardous
machinery can
cause serious
personal injury.
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous
machinery can
cause serious
personal injury.
Failure to stop the pump before
adjusting the shaft packing can cause
severe personal injury.
Hazardous pressure
can cause personal
injury or property
damage
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous or toxic
fluids can cause
serious injury.
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous pressure
can cause personal
injury or property
damage
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause personal injury
or property damage.
Do not operate
without guard
in place
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
PUMP DATA
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA *
SNP(J)1.25
SNP(J)1.5
SNP(J)2
SNP(J)2.5
SNP3A
Maximum Pump Speed
1800 RPM
640 RPM
Maximum Operating
Temperature
240°F (115°C)
240°F (115°C)
Maximum Viscosity
20,000 SSU
(4,250 cSt)
20,000 SSU
(4,250 cSt)
Maximum
Differential Pressure
150 psi
(10.3 Bar)
150 psi
(10.3 Bar)
Maximum
Working Pressure
175 psi
(12.1 Bar)
175 psi
(12.1 Bar)
Maximum
Jacket Pressure
150 psi
(10.3 Bar)
150 psi
(10.3 Bar)
* Technical Data is for standard materials of construction.
Consult Blackmer Material Specs for optional materials of
construction.
INITIAL PUMP START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Inlet Gauge Reading: ____________________________
Discharge Gauge Reading: _______________________
Flow Rate: _____________________________________
Summary of Contents for SNP1.25
Page 15: ...104 A00 Page 15 16 NOTES...