551-A00 Page 7/21
MAINTENANCE
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous voltage.
Can shock, burn or
cause death.
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage.
Systems with meters will still
be pressurized even after the hose is
emptied
Hazardous pressure
can cause serious
personal injury or
property damage
NOTICE:
Maintenance shall be performed by qualified technicians
only, following the appropriate procedures and warnings as
presented in this manual.
Periodic Inspection
Periodic Inspection of the Pump, Pump System and Ancillary
Equipment is required to maintain safety, conformity, operational
functionality and reliability. Blackmer recommends a maximum
interval of three months or 500 hours operation between routine
periodic maintenance inspections (More frequent inspections
may be necessary dependent upon usage, site conditions,
operation, etc.).
If any abnormal condition is discovered, cease operation of
pump immediately and take action to rectify the problem. Record
observations from these inspections in Pump Run Log.
For safe operation, the following items should be included in the
routine periodic inspection:
a. Inspect the Pump for LPG leaks, vibration, abnormal noises,
signs of overheating, discoloration, etc.
b. Inspect Coupling Assembly for signs of wear, overheating,
discoloration, etc.
c. Check Pump differential pressure
d. Check
Motor
Current.
e. Inspect motor for vibration, abnormal noises, signs of
overheating, discoloration, etc.
STRAINERS
Strainers must be cleaned regularly to avoid pump starvation.
Schedule will depend upon the application and conditions.
LUBRICATION
The Ball Bearings for the RC Series pumps are grease
lubricated and 'sealed-for-life' design.
No 'in service' lubrication is required on Ebsray's RC Series
Pumps.
For motor, refer to specific motor manufacturer's
recommendations.
BALL BEARINGS
Bearing Replacement recommended not exceeding 10,000
operational hours.
Summary of Contents for EBSRAY RC20
Page 17: ...551 A00 Page 17 21 ...