Preintstallation
Installation
Startup
Maintenance
Troubleshooting Guide
Blackhawk Technology Company
V-2PneumaticPistonPumpI&O-10365 | 20220811
29
FIGURE 2: Liquid Fill Time Per Pump and Riser Pipe Type
FIGURE 1: Flow Rate vs Depth Per Downhole Type
Liquid Fill Time Per Pump & Riser Pipe Types
(Based on 100' well depth)
Pump Barrel Size
Actuator Type
gpm
Riser Pipe Type and Size
HDPE DR 11 Pipe
Schedule 40 Pipe
1-1/2"
2"
1-1/4"
2"
101
Apollo
1.10
8:12
13:06
6:32
15:19
Pneumatic
2.00
4:30
7:12
3:35
8:25
Anchor
1.35
6:41
10:40
5:19
12:29
102
Apollo
2.70
3:20
5:20
2:39
6:14
Pneumatic
5.00
1:48
2:53
1:26
3:22
Anchor
3.27
2:45
4:24
2:12
5:09
FLOW vs. DEPTH
V-2 101, 102, and 103
@ 100 PSIG
Flow (gpm)
TDH (feet of water)
0
1
2
3
4
5
6
7
8
9
10
11
12
50
100
150
200
500
600
Model 103 - 84’
Model 102 - 243’
Model 101 - 555’